Self-Diagnosis Function - Sony HDR-CX720V Service Manual

Digital hd video camera recorder
Hide thumbs Also See for HDR-CX720V:
Table of Contents

Advertisement

1-5. SELF-DIAGNOSIS FUNCTION

1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service
mode display.Details of the self-diagnosis functions are provided in the
Instruction manual.
LCD screen
Blinks at 3.2 Hz
C
3 2
0 0
Repaired by:
Block
C : Corrected by customer
Indicates the appropriate
Refer to "1-5-3. Self-diagnosis Code Tabl e".
E : Corrected by service
step to be taken.
engineer
E.g.
13 ....
Format the "memory card".
32 ....Turn on power again.
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
C
0
4
0
0
Non-standard battery is used.
C
0
6
0
0
The battery pack temperature is high.
Memory card is unformatted.
C
1
3
0
1
Memory card is broken.
C
1
3
0
2
*
Access error
C
1
3
0
3
*
Access error (External mdedia)
C
1
3
0
4
*
Drive fault (External mdedia)
C
3
2
6
0
Difficult to adjust focus
E
(
6
1
0
0
)
(Cannot initialize focus)
E
2
0
0
0
Flash memory data are rewritten.
E
3
1
0
0
Drive fault
*
Note 1: Start the Adjust Manual in the Adjust Station and refer to the "DESTINATION DATA WRITE".
Note 2: Functions of codes with * mark are not provided in this unit.
HDR-CX720V/CX730E/CX740E/CX740VE/CX760E/CX760V/PJ710/PJ710V/PJ710VE/PJ720E/PJ740VE/PJ760/PJ760E/PJ760V/PJ760VE_L2
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the "repaired
by:", "block" in which the problem occurred, and "detailed code"of the
problem.
Detailed Code
Correction
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Format the memory card.
Insert a new memory card.
Remove the power source. Reconnect it again and operate your cam-
corder again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Retry turn the power on by the power switch. If it does not recover,
check the focus MR sensor of lens block (pin 2, qf of CN4003 on the
LD-297 board). If it is OK, check the focus motor drive IC (IC1301 on
the VC-658 board).
Make flash memory data correct value. (Note 1)
Turn power off and turn power on again.
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Reset position detection error on the stepper
E
6
1
3
0
iris initializing
Handshake correction function does not work
E
6
2
0
0
well. (With PITCH angular velocity sensor
output stopped.)
Handshake correction function does not work
E
6
2
0
1
well. (With YAW angular velocity sensor
output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller com-
E
6
2
0
3
munication abnormality among.
I m a g e v i b r a t i o n c o r r e c t i o n d u r i n g
E
6
2
0
4
handshake function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
9
1
0
1
Abnormality when flash is beingcharged.
E
9
1
0
2
Abnormality of LED Video light.
Abnormality of LED Video light Tempera-
E
9
1
0
3
ture detection.
Battery current value goes over the max
E
9
2
0
1
discharge current
Fault of writing or erasing the flash mem-
E
9
4
0
0
ory
1-4
– ENGLISH –
Correction
Inspect the lens block zoom sensor signal (pin 1, qh of CN4003 on
the LD-297 board when zooming is performed when the zoom lever
is operated, and the zoom motor drive circuit (IC5201 on the LD-297
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive
block (pin 5, qz, qk, ql, wk, wl of CN4003 on the LD-297 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of "E: 61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
tween CN6701 on CM-121 board and CN1004 on VC-658 board
by FP-1520 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
Inspect PITCH angular velocity sensors (SE7501 on the LD-297
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7501 on the LD-297 board)
peripheral circuits.
Refer to [1-6-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
Inspect the steadyshot circuit (IC5601 on the LD-297 board).
Inspect the image vibration angular velocity sensors (SE7701 on the
CK-244 board) peripheral circuits.
Replacement of lens block (Note 3).
If an error occurs again, replace the LD-297 board.
Refer to [1-6-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
Refer to [1-6-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
Refer to [1-6-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
Check or replace the LED Flash/Video light or charging capacitor.
Check or replace the LED Flash/Video light or charging capacitor.
Check or replace the LED Flash/Video light or charging capacitor.
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each
output of DC/DC converter (IC4301 on the VC-658 board) with
connected the DC JACK (J901) on the VC-658 board.
(The minimum connection to periphery)
CX740VE/PJ710/PJ710V/PJ710VE/PJ740VE:
Inspect the flash memory (IC8101 on the MM-102 board).
CX720V/CX760E/CX760V/PJ720E/PJ760/PJ760E/PJ760V/
PJ760VE:
Inspect the flash memory (IC8101, IC8201 on the MM-102 board).