1-3. CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1. Turn on the power of the unit.
2. Perform the following operations.
[MENU]→[Camera/Mic]→[
Shooting Assist]→[Ctrl with Smartphone]
3. When preparation for Wi-Fi has been completed, the following screen opens and a password for Wi-Fi connection is displayed.
Ctrl with Smartphone
Wi-Fi
Operate smartphone to connect to
this device via Wi-Fi.
SSID DIRECT-XXXX:HDR-XXXX
Password XXXXXXXX
Device Name HDR-XXXX
4. Confirm on the personal computer that the unit is detected as a connectable wireless network.
5. To further confirm that the unit is connectable, connect the unit to the personal computer and double-click the "current connection" from the icon
displayed on the notice field, make sure that the unit is displayed in the Wireless internet access column.
HDR-CX330/CX330E/PJ330E/PJ340/PJ340E/PJ350/PJ350E_L2

1-4. SELF-DIAGNOSIS FUNCTION

1-4-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the Viewfinder or the LCD
screen what to do.
This function consists of two display; self-diagnosis display and service
mode display. Details of the self-diagnosis functions are provided in the
Instruction manual.
Viewfinder or LCD screen
Blinks at 3.2 Hz
C
3 2
0 0
Repaired by:
Block
C : Corrected by customer
Indicates the appropriate
E : Corrected by service
step to be taken.
engineer
E.g.
13 ....
Format the "memory card".
32 ....Turn on power again.
1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
C
0
4
0
0
Non-standard battery is used.
C
0
6
0
0
The battery pack temperature is high.
Memory card is unformatted.
C
1
3
0
1
Memory card is broken.
C
1
3
0
2
Access error
*
C
1
3
0
3
*
Access error (External media)
C
1
3
0
4
*
Drive fault (External media)
C
3
2
6
0
Difficult to adjust focus
(
E
6
1
0
0
)
(Cannot initialize focus)
E
2
0
0
0
Flash memory data are rewritten.
E
3
1
0
0
Drive fault
*
E
4
1
0
0
Wi-Fi Module Hardware Error
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
Note 1: Start the Adjust Manual in the Adjust Station and refer to the "DESTINATION DATA WRITE".
Note 2: Functions of codes with * mark are not provided in this unit.
1-2
1-4-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
Viewfinder or the LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character display
indicates the "repaired by:", "block" in which the problem occurred, and
"detailed code" of the problem.
Detailed Code
Refer to "1-4-3. Self-diagnosis Code Tabl e".
Correction
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Format the memory card.
Insert a new memory card.
Remove the power source. Reconnect it again and operate your cam-
corder again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Retry turn the power on by the power switch. If it does not recover, check
the focus drive signal of lens block (pin ek of CN4002 on the VC-1025
board). If it is OK, check the focus motor drive IC (IC6800 on the VC-
1025 board).
Make flash memory data correct value. (Note 1)
Turn power off and turn power on again.
Check that connection between CN4902 on the VC-1025 board and
CN2301 on the WF-1004 board by FP-2200 flexible board.
Inspect the lens block zoom drive signal (pin eg of CN4002 on the VC-
1025 board when zooming is performed when the zoom lever is operated,
and the zoom motor drive circuit (IC6800 on the VC-1025 board) when
zooming is not performed.