Audio connector panel
Attach the supplied audio connector panel as
follows.
Notes
• Attach/remove the audio connector panel while the
camcorder is turned off.
• When attaching the audio connector panel, make sure
not to catch the cap.
• When removing the audio connector panel, pull it
away slowly from the body of the camcorder, as shown
in the diagram above.
• Applying excessive force to remove the audio
connector panel may damage it.
Settings of the AUDIO IN CH1/AUDIO IN CH2 switch and recorded channels are as below.
AUDIO IN CH1/CH2 switch
CH-1
CH-2
LINE/MIC
LINE/MIC
AES/EBU
LINE/MIC
LINE/MIC
AES/EBU
AES/EBU
AES/EBU
LINE1/MIC1: LINE or MIC signal that is input to CH-1
LINE2/MIC2: LINE or MIC signal that is input to CH-2
AES/EBU1-x: Channel x signal of the AES/EBU signal that is input to CH-1
AES/EBU2-x: Channel x signal of the AES/EBU signal that is input to CH-2
1
2
1.
AUDIO IN CH1/AUDIO IN CH2
(external audio input selection) switches
Switch input signal (external microphone,
external audio device, etc.).
LINE: Line input audio equipment
AES/EBU: AES/EBU format audio signal
MIC: Microphone input
2.
AUDIO IN (CH-1, CH-1/2) /AUDIO IN
(CH-2, CH-3/4) connectors
Input external microphone or audio
equipment signals.
3.
CH1 MIC +48V/OFF, CH2 MIC +48V/
OFF (external microphone input
selection) switches
Supply phantom power (48 V) to the external
microphone when you set this switch to
"MIC +48V."
Recorded channel
CH-1
CH-2
LINE1/MIC1
LINE2/MIC2
AES/EBU1-1
AES/EBU1-2
LINE1/MIC1
No sound
AES/EBU1-1
AES/EBU1-2
CH-3
CH-4
No sound
No sound
No sound
No sound
AES/EBU2-1
AES/EBU2-2
AES/EBU2-1
AES/EBU2-2