PROTECTION MODES
Your air-conditioner includes several auto protection modes which enables you to use it virtually at any time
and in any season regardless of the outdoor temperature. Some of the protection modes are listed below:
Mode
Operation
conditions
Cooling and
Low outdoor
Dry
temperature
High outdoor
temperature
Heating
Low outdoor
temperature
High Indoor
or outdoor
temperature
Note: When switching the unit to OFF after heating operation, the unit may perform outdoor coil deicing
operation. In such a case, the compressor will continue to run for some time after the unit has switched to
OFF, and the indoor unit louvers are closed. This feature is a part of the normal unit operation.
6
Protection
Controlled
from
remedy
Indoor coil
Stops outdoor fan and compressor when
freezes up
approaching freezing conditions Resumes
operation automatically.
Outdoor coil
Stop compressor when approaching over
overheating
heating conditions. Resumes operation
automatically. Operating indicator (A)
blinks.
Outdoor coil
Reverses operation from heating to cooling
ice build up
for short periods to de-ice outdoor coil.
Operating indicator (A) blinks.
Indoor coil
Stops outdoor fan and compressor when
overheating
approaching high indoor coil temperature.
Resumes operation automatically.
CONTENT
APPENDIX A