Electra DCR 25 Service Manual page 40

Hide thumbs Also See for DCR 25:
Table of Contents

Advertisement

11.13
SW Parameters
11.13.1
Indoor Units SW Parameters
General Parameters for All Models:
Parameters defining the indoor fan speed as a function of Indoor Coil temperature in heat mode
(ICT):
ICTST Speed
ICT to stop indoor fan
ICTVLSpeed
ICT to go down to very low speed
ICTLSpeed
ICT to start in very low speed
ICTHSpeed
ICT to start in increase speed from very low
ICTTSpeed
ICT to enable Turbo fan speed
Parameters for defrost protection:
ICTDef1
ICT to go back to normal
ICTDef2
ICT to 'stop rise' when ICT decrease
ICTDef3
ICT to 'stop rise' when ICT is stable
ICTDef4
ICT to 'Hz Down' when ICT decrease
ICTDef5
ICT to 'Hz Down' when ICT is stable
ICTDef6
ICT to stop compressor
Parameters for indoor coil over heating protection:
ICTOH1
ICT to go back to normal
ICTOH2
ICT to 'stop rise' when ICT increase
ICTOH3
ICT to 'stop rise' when ICT is stable
ICTOH4
ICT to 'Hz Down' when ICT increase
ICTOH5
ICT to 'Hz Down' when ICT is stable
ICTOH6
ICT to stop compressor
Model Depended Parameters:
Parameter name
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C
MaxNLOADIF2C
MaxNLOADIF3C
MaxNLOADIF4C
MaxNLOADIF5C
IFVLOWC
IFLOWC
IFMEDC
IFHIGHC
IFTURBOC
IFVLOWH
IFLOWH
IFMEDH
IFHIGHH
IFTURBOH
Nominal Compressor Frequency
NomLoadC
NomLoadH
Service Manual - Delta DCI
Models
22
25
40
40
55
51
120
90
127
127
127
127
Indoor Fan speeds
700
700
800
850
950
1050
1050
1200
1150
1250
700
700
850
950
1000
1050
1100
1250
1200
1350
40
51
55
58
Revision Y05-01
CONTENT
CONTROL SYSTEM
25
28
30
32
40
8
6
4
2
0
-2
45
48
52
55
60
62
35
40
55
90
127
127
700
850
1000
1200
1250
700
950
1100
1250
1300
61
62
11-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Delta 25Dcr 35Delta 35

Table of Contents