Plasmacluster Ion Generator OPERATION MANUAL Plasmacluster is a registered trademark or a trademark of Sharp Corporation. Plasmacluster 乃 Sharp 株式會社的註冊商標或 商標。 HD PCI 抗菌機 IG-DC2A 使用說明書 *1 The number on this technical mark indicates the number of ion count per 1cm blown out to the air, which is measured near the center of space (0.5m height from...
It cannot be used in vehicles with DC 24V batteries (buses, trucks, etc.). * Replacement is required approximately every 6 years (17,500 hours) when operated 8 hours a day. IG-DC2A will stop operating after about 6 years and 6 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.
• When transporting, be careful not to drop the unit or subject it to shocks. (Doing so could cause injury or damage.) If the unit should drop or get damaged, contact your store of purchase or SHARP authorized service center.
If this happens, remove the dust from the electrode section of the Plasmacluster Ion Generating Unit. (See E-9) * Hair care products (split end coatings, hair mousses, hair treatments, etc.), cosmetics, antiperspirants, antistatic agents, waterproofi ng sprays, polishes, glass cleaners, chemical- impregnated clothes, wax, etc. IG-DC2A.EN.indd 5 IG-DC2A.EN.indd 5 2012/04/11 10:54:04 2012/04/11 10:54:04...
Do not remove Cord the cushioning material from the Cigar Plug back of the cover. (With 5A glass tube fuse) Connect to the cigar lighter socket in the vehicle. Air Intake (Filter) IG-DC2A.EN.indd 6 IG-DC2A.EN.indd 6 2012/04/11 10:54:04 2012/04/11 10:54:04...
Insert the cigar plug into the cigar lighter socket. Cigar lighter Cigar socket plug • Be sure to remove any dirt from the cigar lighter socket. Failure to do so could cause faulty contact or fi re. IG-DC2A.EN.indd 7 IG-DC2A.EN.indd 7 2012/04/11 10:54:05 2012/04/11 10:54:05...
Page 8
• If the unit is installed directly in front of the car climate control’s outlets, the unit could get hot when the climate control is operating in the heating mode. • The unit could get scratched by the vibrations of the vehicle, etc. IG-DC2A.EN.indd 8 IG-DC2A.EN.indd 8 2012/04/11 10:54:06...
8 hours from the operation is started, however, if the main unit is operated even if the key of the vehicle is pulled out or the engine switch is turned OFF, pull out the cigar plug for preventing the dead battery. IG-DC2A.EN.indd 9 IG-DC2A.EN.indd 9 2012/04/18 17:44:31...
Every month or more often if necessary Wipe with a dry soft cloth. <For Stubborn Dirt> Use water and a mild detergent. And then, wipe with a wet cloth. Make sure to dry out the main unit. Every IG-DC2A.EN.indd 10 IG-DC2A.EN.indd 10 2012/04/11 10:54:06 2012/04/11 10:54:06...
Page 11
* Places where hair care products (split end coatings, hair mousses, hair treatments, etc.), cosmetics, antiperspirants, antistatic agents, waterproofi ng sprays, polishes, glass cleaners, chemicalimpregnated clothes, wax, etc. are used or smoking environment. IG-DC2A.EN.indd 11 IG-DC2A.EN.indd 11 2012/04/11 10:54:07 2012/04/11 10:54:07...
Page 12
Plasmacluster Ion Generating Unit Please dispose the used Plasmacluster Ion Generating Unit according to any local Model Number: laws and regulations. -materials- IZ-C75CE • Case : Polystyrene • Unit : Polystyrene Terephthalate, Electric parts E-10 IG-DC2A.EN.indd 12 IG-DC2A.EN.indd 12 2012/04/11 10:54:07 2012/04/11 10:54:07...
• After the replacement, you may feel the sound “Zi, Zi ...”(sound generated by Plasmacluster ion) become larger, however, you feel it because the Plasmacluster Ion Generating Unit is replaced with a new one. It is not a failure. E-11 IG-DC2A.EN.indd 13 IG-DC2A.EN.indd 13 2012/04/11 10:54:08 2012/04/11 10:54:08...
*2 Space corresponding to a cabin measuring 1.5 (width) x 2.4 (depth) x 1.0 (height) meters * Some specifi cations may be changed for improvement purposes. ACCESSORIES Car Adapter / Operation manual E-12 IG-DC2A.EN.indd 14 IG-DC2A.EN.indd 14 2012/04/11 10:54:09 2012/04/11 10:54:09...
Pull out the Plasmacluster Ion Generating Unit and insert it to the end again, and then press the Operation Button. (See E-11) If the light fl ashes repeatedly, contact the store you purchased or SHARP authorized service center. E-13 IG-DC2A.EN.indd 15 IG-DC2A.EN.indd 15...
Page 16
Plasmacluster ion is not changed. • Dust may block the fi lter, clean the fi lter. (See E-8) Other indication • Failure Unplug and contact the store you purchased or SHARP authorized service center. E-14 IG-DC2A.EN.indd 16 IG-DC2A.EN.indd 16 2012/04/11 10:54:10 2012/04/11 10:54:10...
Page 17
• 為穩定釋出高濃度的 P C I,需要定期更換安裝於 I G - D C2A 內部的 H D 離子產生器 *。 * 在 8 小時連續運行的情況下,大約每 6 年(17,500 小時)需要進行一次更換 ; 如果未對 HD 離子產生器進行更換,IG-DC2A 將在大約 6 年 6 個月(19,000 小 時)後停止運行。 感謝您購買 SHARP 生產的 HD PCI 抗菌機。在使用 HD PCI 抗菌機前請詳細...
Page 46
ﻛﺘﻴﺐ ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺸﻐﻴﻞ ١* ﳌﻮﻟﺪ ﺃﻳﻮﻧﺎﺕ ﺑﻼﺯﻣﺎﻛﻠﺴﺘﺮ Plasmacluster is a registered trademark or a trademark of Sharp Corporation. IG-DC2A *1 The number on this technical mark indicates the index of ion count per 1cm blown out to the air, which is measured near the center of space (0.5m height from floor) when...
Need help?
Do you have a question about the IG-DC2A and is the answer not in the manual?
Questions and answers