Scantronic 601 Installation And Programming Manual page 6

Hide thumbs Also See for 601:
Table of Contents

Advertisement

(see Figure 2). Note that you can disable the Personal Attack signal from the
keypad during programming.
Note: The 602 is supplied complete with one 625 remote keypad.
Keypad Closed
Sounders. The panel uses a loudspeaker fitted inside the case to give alarm
and entry/exit tones. You can connect a remote boxed speaker to the speaker
terminals.
System Reset. When delivered from the factory the panel allows the customer
to reset it after an alarm. If necessary you can program it for engineer only
reset.
Zone Types. You can program any zone as one of seven types. Each type
operates as follows:
a)
Normal Alarm causes an instant alarm when the panel is set.
b)
24 Hour Zone causes an instant alarm whether the panel is set or un-set.
The alarm is internal only when the panel is un-set.
c)
Entry Route Zone causes a full alarm if the panel is set. However, if the
entry timer is running then the panel inhibits this zone. Use for detectors
between the entry door and the panel.
d)
Entry/Exit Zone starts the entry timer if the panel is set.
e)
PA Zone causes an instant alarm whether the panel is set or un-set.
f)
Fire Zone causes an instant alarm whether the panel is set or un-set, and
pulses any external sounder.
g)
Technical Alarm causes an instant alarm whether the panel is set or un-
set, and triggers the internal sounder.
Keypad Open
Fig 2. 625 Remote Keypad
496219 Issue 1
Write zones
here
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

602

Table of Contents