2-Ply Entry Timer. You can program the panel to give a 30 second internal
alarm if the user over-runs the programmed entry time. The user must unset
the panel before the warning ends, or the panel will give a full alarm.
Entry Route. The panel can be programmed to inhibit detectors on the route
between the final door and the keypad during the entry time.
Duress code. When the user enters a duress code, the panel sets or unsets,
and also triggers a PA output for remote communications.
Entry/Exit Times. You can program entry and exit delays independently. Each
can be up to 60 seconds long.
Entry/Exit Zones. You can program any zone as an Entry/Exit zone. Activating
an Entry/Exit zone when the panel is set starts the Entry timer. The user must
enter their Access Code before the timer expires or the panel will raise an
alarm.
External Bell. The panel can be connected to a Self Activated Bell (SAB) using
standard bell cable. The SAB draws power from the panel, and contains an
internal battery that will operate the sounder if intruders cut the supply. The
maximum current available is 500mA. The trigger for a SAB is negative applied
in alarm.
You can program a delay between a detector being activated and the panel
triggering the bell, and also the length of the time the panel continues to
operate the external bell.
Full Set Exit Mode. When programmed for 'Final Door' exit mode the user
must enter their access code and close the final door. The panel sets when the
door closes. When programmed for 'Timed or Terminate' exit mode, the panel
starts the Exit timer when the user enters their access code. At the end of the
programmed exit time the panel sets. If a terminate button is fitted, the user
can press that to cut short the exit timer and set the system.
Keyswitch. The user can full set, part set, unset, or reset the panel using a
keyswitch. For this use a three position keyswitch. The panel has programming
options for momentary or fixed position keyswitch operation.
Loading Defaults. You can restore the panel to its factory default program by
using a programming command. See 'Programming - Restore Factory
Defaults' for more details.
Omit. You can program the panel to let the user omit individual zones, see
Zone Attributes below for more information.
Outputs. The panel provides open collector transistor outputs labelled Bell,
Strobe and OP1. OP1 can be programmed for one of the following options:
496219 Issue 1