Initial Power Up - Scantronic 601 Installation And Programming Manual

Hide thumbs Also See for 601:
Table of Contents

Advertisement

Initial Power Up

Before applying power to the panel make sure that:
All used circuits are connected.
The Bell trigger is NOT connected to the external sounder.
The battery or speech communicator (if fitted) is NOT connected.
The global anti tamper circuit is closed and the tamper return (TR)
is linked to 0V.
Note: The panel will not enter programming mode if the global anti tamper is
open circuit, or if the negative tamper return is not present.
1.
Close the 601 (or 602) lid or defeat the lid tamper.
2.
Apply mains power to the 601/602.
The Power LED comes on.
3.
Key in the default user code (1234) if there is an alarm. Ignore any LEDs
that are lit at this stage.
4.
For a 601:
Key in
0 + ENTER + the engineer code (default 7890).
The panel bleeps once per second.
Open panel lid or release the panel tamper.
The panel bleeps twice and all the LEDs flash.
You are now in Programming Mode.
5.
For a 602 with 625 keypad:
Key in
0 + ENTER + the engineer code (default 7890).
The keypad bleeps once per second.
Open 602 end station lid or release the tamper.
The 602 bleeps twice if a 9040 sounder is fitted. (Keypad LED's do not
flash.)
You are now in Programming Mode.
6.
Connect the battery and make any final wired connections (for example
bell trigger to the external sounder, or communicator harness to main
pcb).
7.
Remember to remove any link between 0V and TR if you are fitting a
SAB.
18