Control panel
Z1
Z2
A/T
A/T
12V
0V
Fitting and Wiring Remote Keypads
Figure 9 shows the connector inside of the 625 remote keypad.
CONTROL PANEL
Stb Bell 12V 0V TR LS
Note: 625 keypad is supplied
with the 602 panel.
1.
Remove the front of the keypad from the back.
2.
Fix the back box to a smooth surface at a convenient height for the user.
3
Connect wiring from the panel to the to the keypad connector.
4.
Wire the second keypad, if fitted, in parallel to the first. Connect the
cable either at the first keypad (daisy chain) or at the panel (star). The
maximum cable length is 100m.
14
Surface contact
Figure 11. Connecting Door Contacts.
Sounder
Volume
Control
LS OP1 SIG ARM RDY
Figure 9. Connecting Remote Keypads
496219 Issue 1
Note: If only one
contact is fitted, wire
it as last contact.
625 Keypad Circuit Board
I/P SIG 0 V +V
To next keypad
if using daisy
chain wiring
Normally open
push to make
exit terminate button