14-CLEANING AND MAINTENANCE
END-OF-SEASON SHUTDOWN
At the end of season, before shutting down the boiler, we recommend completely removing pellets from the tank with the use of a
vacuum cleaner with an extension.
When starting up the boiler at the beginning of the season, if the control panel display fails to light up when you press the power switch
(located on the back of the boiler), it could mean that the service fuse needs replacing.
On the rear of the boiler there is a fuse holding compartment which is located underneath the supply socket. Use a screwdriver to open the
fuse-holder compartment and if necessary replace them (3.15 A delayed)
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out with a scheduled service contract. This service is essentially a visual and
functional inspection of the following components: The following is a summary of the checks and/or maintenance that are indispensable
for the correct operation of the product.
Gearmotor
Smoke extractor fan
Smoke probe
Ignition spark plug
Pellet/water automatic rearm thermostat
Room/water temperature probe
Motherboard
Fuses protecting panel-motherboard
Wiring
64