14-CLEANING AND MAINTENANCE
CLEANING THE EXCHANGER AND THE COMPARTMENT BENEATH THE BRAZIER
Cleaning the exchanger and the compartment beneath the brazier is a simple operation but very important if the boiler is to maintain
optimal performance.
We therefore recommend cleaning the internal exchanger every week, performing these simple operations in sequence:
Activate the "CLEANING" function - with the boiler off press - menu, select "Settings", with the arrows <> select "Cleaning",
confirm with the "Menu" key, activate the cleaning "ON" with the + - keys. This procedure starts the smoke extractor on the
maximum setting to expel the soot that becomes dislodged when the exchanger is cleaned.
Clean the pipe unit - Use the handle to clean, located on the left side of the boiler. Shake the handle forward and backward about
5 times. This will remove any soot that has deposited in the exchanger's smoke ducts during normal boiler operation.
Deactivate the "CLEANING" function - this function is deactivated automatically after two minutes. If you need to stop the
function sooner, press the "Esc" key.
Clean the smoke conveyor compartment (fig.2) - The boiler is equipped with two removable ash pans. To access the ash pans:
open the aesthetic door "C", remove the protection "I" by simply lifting the handle (figure 2) and remove the two pans "G" and "H".
Once cleaning is complete, put the pans "G" and "H" and the protection "I" back.
If cleaning is not done every week, the boiler could go into alarm caused by ash clogging after several hours of
operation.
HANDLE FOR CLEANING
Figure 1
Technical Dept. - All rights reserved - Reproduction is prohibited
C
I
Figure 2
G
H