Direct Address Programming Example

Example: Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.
DETERMINE THE DATA ENTRIES
!
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5
through 8 are located at address 1218, left digit. Circle
!
2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, "14" (E) is entered as press
. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as a
G4
blank (•).
ZONE OPTION
EXIT/ENTRY FOLLOWER
PROGRAM THE DATA ENTRIES
!
1. Enter the panel's Dealer Security Code (Address 0500), then press the
!
2. Answer NO (
F
NOTE: If you pass "ACTIVATE PROGRAM", scroll backward using the the
!
3. Press the
C
!
4. Press
1 2 1 8
will advance to the data field.
!
5. Press
G 4
J
!
6. Press
to save.
Address 1218 is now programmed with "E•".
X
GEM-X255 Programming Instructions
ZONES
LEFT DATA VALUES
SUM = 14 (CIRCLE
ZN08
ZN07
ZN06 ZN05
$
#
"
) to all questions until "ACTIVATE PROGRAM Y/N" is displayed; then press YES (
button to enter the Address Program Mode. Address "0000" will display.
to access Address 1218. The data for both digits will display and the cursor
to enter an "E" in the left digit and press
"
the data values for Zones 5–8.
ADDRESS
"
1218
)
L
ADDR
R
1
E
1218
blank (•)
"
ENTER DATA
B
to enter a blank (•) in the right digit.
0
WI1092B 9/02
ZONES
RIGHT DATA VALUES
"
)
SUM = 0 (CIRCLE
ZN04
ZN03
ZN02 ZN01
8
4
2
1
button.
A
E
button.
L