DIRECT ADDRESS PROGRAM MODE

This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the
Keypad Programming Worksheets that follow. Refer to these worksheets to identify the 4-digit location (address) of
the feature to be programmed. An illustrative example is provided on the next page.
DATA ENTRY
ADDRESS
LOCATIONS
LEFT DIGIT
0000
3
HEXADECIMAL DATA:
0000
BLANK (•) = No Options
TO
1 to 9 = Entries 1 to 9
0 = Entry of 10
4093
B to F = Entries 11 to 15

ACCESSING DIRECT ADDRESS PROGRAM MODE

1. Press EEEEEE A
2. Press g Until "ACTIVATE PROGRAM Y/N" appears on the keypad display.
3. Press F To Enter Dealer Program Mode
DIRECT ADDRESS PROGRAM MODE DISPLAY & COMMANDS
X
GEM-X255 Programming Instructions
LOCATIONS
RIGHT DIGIT
C
(printed on microprocessor can)
Dealer Security Code (Address 0500)
KEYPAD PROGRAMMING
OVERVIEW
Direct Address Programming allows you to go directly to the
address locations and change the data entries to customize
your control panel options. Whereas the Easy Menu Program
Mode is a simple quick start guide with limited options, the
Direct Address Program Mode is more flexible allowing you to
change all the options.
It consists of multiple address locations (up to 4093) with two
data entry locations each (left and right) as shown in the
adjacent diagram.
Master Security Code
or
1
2
0 0 0 0 3 C ( S E C O N D S )
0000 3C
WI1092B 9/02
GEMINI
AI #ZN =08 #KP=1
SYSTEM ARMED
# OF ZONES IN AREA 1
A2 #ZN=00 #KP=0
01/01/97
ENTER # ZONES X X
A
1 2
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
1
= ADDRESS
2
= DATA ENTRY
LOCATION
(Left and Right
L
NAPCO Security Systems
12:00AM
NEXT/YES
3
E
D
PRIOR/NO
F
AREA
G
R

Hide quick links: