GENERAL DESCRIPTION
HA-263K owner requires no study of this section. All information is for HA-263D only.
HA-263D is the version comes with a digital control keypad which allows owner to program two
independent user codes for partition 1, 2 and the common partition; and also one user code for
the whole system in arm-disarm control. Apart from that the system also gives the following
Additional features:
1)
Set up Master Code for programming authorization.
2)
Software panic button -- press any two buttons simultaneously for more than 3 seconds to
give alarm.
3)
Make bypass to the un-used zone(s) and the faulty zone(s).
4)
Put the habitually bypassed zone(s) in memory for HOME mode.
5)
Make system to show the faulty zone(s) during disarmed condition with user code.
6)
Make system to arm instantly without delay.
7)
Clear the alarm memory in the specific partitions or in the whole system.
8)
Initiate dynamic battery test at anytime during disarmed mode.
9)
Initiate a 5-second operation of both timing and latch output relays to test the connected
siren and strobe light.
10)
System Code for Direct Access to Programming mode in case of the Master Code is forgotten.
THE DIGITAL CONTROL KEYPAD
The "System Setting Jumper" on the main circuit board MUST be set on "DK" Position for keypad
only or keypad + keyswitch operation.
16
HA-263D
SYSTEM
SUMMARY OF THE VISUAL AND AUDIBLE NOTIFICATIONS
THE ZONE STATUS LEDS FOR PARTITION 1 AND 2
EVENTS
System disarmed
Zone abnormal during Exit Delay Period, check the circuit loop
immediately
All zones normal during Exit Delay Period
System armed after Exit Delay expired
System is or was in alarm (alarm occurred)
System in alarm memory
System is forced to arm and the abnormal zone(s) is isolated
by the system
System in power-up delay or in Standby mode
NOTE:
F
The Zone Status LED of the later turned-on partition also shows the status of the Common
zones. As the common partition follows the later partition to arm.
F
The alarm indication of zone 7 goes to the later armed partition
F
The alarm indication of zone 8 (24 hour) goes to both partitions.
THE SYSTEM STATUS LED (SHOWING THE SYSTEM STATUS ALL THE TIME)
EVENTS
AC power and battery power normal
AC power failure
Battery Low
Battery under testing
System in Standby mode
4
HA-263
HA-263
INDICATIONS
OFF
ON
Flash
2 Short Flashes/Second
Fast Flashes
3 Short Flashes/Second
ON
Flashes Alternatively with
System Status LED
INDICATIONS
ON
2 Flashes with one
second pause
3 Flashes with one
second pause
Flash
Flashes Alternatively with
Zone Status LEDs
13