THE AUDIBLE NOTIFICATIONS
EVENTS
System in Exit Delay Period
OR
System in Entry Delay Period
System in Standby Mode Period
System is or was in Alarm condition
(Alarm occurred)
Successful Key-switch operation
OR
Battery is Normal after Testing
AC power Failure
Battery Low After Testing
14
SUMMARY OF THE VISUAL AND AUDIBLE NOTIFICATIONS
NOTIFICATIONS
Exit And Entry Beeps
!
Short beeps at 0.5 second interval
!
Increase to 4 beeps/second at the last 10
seconds, then
!
One long beep to indicate the end of the
delay period
!
Short beeps at 0.5 second interval
!
Increase to 4 beeps/second at the last 10
seconds, then
!
One long beep to indicate the end of the
period
NOTE:
The beep stops at anytime when manual battery
test starts or when system is set to programming
mode with the system code (HA-263D)
Warning beeps
!
4 fast beeps at 1 second interval
2 Short beeps
1 Short beep/30 seconds
5 Short beeps first, then
1 Short beep/30 seconds
The HA-263K is protected by a built-in tamper switch. Opening of the cabinet will trigger the
tamper switch to give alarm.
If opening of the cabinet for service is required, it is necessary to set the system to standby
mode by holding the keyswitch in contact for 5 seconds (ignore the 2 arming beeps). The
standby mode lasts for 1 minute and the system gives no function including the tamper switch
during the period. Setting the system to standby mode can only be done while all the partitions
are in disarmed mode without alarm memory existing.
!
Power Source
!
Back-up Battery Requirement
included
!
Temperature Range
!
Standby Current
!
Protection Zones
!
Control Station
!
Entry Delay
!
Exit Delay
!
Alarm Duration
!
Power Up Delay (Standby Mode):
!
Audible Beeps
!
G. Weight
!
Dimensions
4
HA-263
HA-263

OPEN THE CABINET FOR SERVICE

GENERAL SPECIFICATIONS
:
16.5V AC
:
6.5-7.0Ah, 12V Rechargeable sealed lead acid - not
(Built-in Charger in system)
:
0 Deg C to +65 Deg C
:
100mA Typical
:
8 Protection zones in 3+3+2 partitions
:
Key-switches and/or Digital keypads, 4 maximum
:
15-90 Seconds
:
60 Seconds
:
3-15 Minutes, or
60 Seconds
:
Entry, Exit & Alarm Warning, ON-OFF programmable
:
2.5 Kgs (one Master unit & one Control Station)
:
Master unit: 265(W) X 270(H) X 78(D) mm
Key-switch: 73(W) X 117(H) X 43(D) mm
Digital Keypad: 117(W) X 117(H) X 27(D) mm