OPERATION
SYSTEM STANDBY
The system standby period begins right after power-up or set it manually by holding the
keyswitch in contact for more than 5 seconds during the system in disarmed mode. It lasts for 1
minute. During the standby period, the system keeps all its functions in sleeping except the
following two function items:
a)
Manually initiate battery test with the key-switch -- one touch contact
b)
Set system to programming mode with system code (HA-263D only)
!
Zone status LEDs (partition 1 & 2) and system status LED flash alternatively until the end of
the period
!
System generate warning beeps until the end of the period
!
The LED indicators and the warning beeps stop instantly if one of the above two functions
is keyed in, and the system ends the standby mode
!
The system is in disarmed condition after the standby period

ARM THE SYSTEM

a)
Make sure that the alarm system is in disarmed state and has no alarm memory existing in
the protection zone.
b)
Turn the key-switch of Partition 1 or Partition 2 to make contact for more than 0.5 second to
arm the desired partition. If partition 1 and 2 are connected together with one key-switch for
combined control, both partitions will be controlled at the same time.
c)
Hold the key-switch in contact for more than 1/2 second until the system generates two
beeps to confirm that exit delay has began. Release key-switch instantly. The zone status LED
starts to flash. The exit delay is 1 minute fixed.
d)
The system is armed after exit delay expired and the zone status LED gives 2 short
flashes/seconds continuously all the time while the system is armed.
DISARM THE SYSTEM
a)
In the condition of there is no alarm occurred when you come back from outside.
b)
Turn the key-switch to make contact until 2 beeps are heard to disarm the system within the
entry delay period. The zone status LED is OFF. The system is disarmed and ready for next
arming operation.
DISARM THE SYSTEM IN ALARM OR AFTER ALARM
a)
Turn the key-switch to make contact until two beeps are heard to disarm the system and
silence the siren instantly.
b)
The zone status LED gives 3 short flashes/second as alarm memory to show that alarm was
occurred.
c)
Turn the key-switch to make contact once again to clear the alarm memory.
d)
The zone status LED is OFF and 2 short beeps are heard. The system is disarmed and ready
for next arming operation.
12
Control Key Buttons
There are 14 buttons for code entry and function confirmation:
a)
Numeric Buttons, 1 0 --- For code entry
b)
, # --- For function confirmation
c)
HOME --- For home mode arming and programming
d)
BYPASS --- For system arming with zone(s)
Zone Status LEDs 1 8
a)
ON --- Zone Abnormal
b)
OFF --- Zone Normal
c)
Fast Flashing --- Zone is or was in alarm
d)
3 Fast Flashings with Stopping Interval --- Zone was alarmed and is in alarm memory. System
is disarmed.
e)
Slow Flashing --- Zone is bypassed
Exit/Armed LED
a)
ON --- System armed (whole system or one of the partitions)
b)
OFF --- System disarmed (the whole system)
c)
Flash --- System in exit delay period
Partition 1 LED
a)
ON --- Partition 1 armed
b)
OFF --- Partition 1 disarmed
c)
Flash During Exit Delay
Partition 2 LED
a)
ON --- Partition 2 armed
b)
OFF --- Partition 2 disarmed
c)
Flash During Exit Delay
AC Power LED
a)
ON --- AC power normal
b)
Flash --- AC power failure
c)
Flash Alternatively with Battery LED --- System in Standby mode
4
HA-263
HA-263
HA-263D (THE DIGITAL CONTROL KEYPAD)
-
bypassed
-
17