Operation - AEI HA-263K Owner's Manual

8-zone alarm control panel

Advertisement

Battery LED
a)
OFF --- Battery normal
b)
ON --- Battery low
c)
Flash --- Battery under testing
d)
Flash Alternatively with AC power LED --- System in Standby mode
Program LED
a)
ON --- System in programming mode
b)
OFF --- System in normal operation mode
Forced To Arm
a)
OFF --- System armed normally
b)
ON --- System will be forced to arm if the faulty zone is not cleared
c)
Flash --- System forced to arm with the faulty zone(s) bypassed by the system
The Audible Notifications From The Keypad
EVENTS
Successful key entry
Successful code entry for a specific function
!
Unsuccessful code entry
!
Code entry time expired (Maximum Allowable Time:
10 seconds/digit, 60 seconds/code)
Exit delay expired, system is armed
Battery low or AC power failure
During the Exit delay, Entry delay and System Standby
period
After an alarm condition before the system is disarmed
NOTE:
All the above LED visual indications and audible notifications from the keypad are
independent from the indications and notifications of the control panel.
18
HA-263D (THE DIGITAL CONTROL KEYPAD)
NOTIFICATIONS
1 short beep
2 short beeps
5 short beeps
1 long beep
1 short beep/30 seconds
!
Continuous short beeps at 0.5
second interval
!
Beeping increases to 4
beeps/second at the last 10
seconds
!
1 long beep at the end of the
period
4 short beeps with 1 second
interval
HA-263
4) AUDIBLE BEEPS
There are 3 jumpers for ON-OFF selection of Entry Beep, Exit Beep and Warning Beep
independently.
a) Entry Beep
--- Beeps during the entry delay period.
AUDIBLE
b) Exit Beep
--- Beeps during the exit delay period.
BEEPS
c) Warning Beep
--- The system offers two modes of warning beep
i)
The system gives warning beeps in alarm period and it stops the beeps
ON
OFF
when the alarm period expires if only one of the partitions is armed.
ENTRY BEEP
ii)
The system gives warning beeps in both alarm period and after alarm
ON
OFF
period if both partitions are armed. The system stops the warning
EXIT BEEP
beeps when one of the partitions is disarmed. It prevents noise
disturbance to the people at the other partition in house.
ON OFF
The after alarm warning gets the owner to pay attention on his alarm
WARNING BEEP
that was triggered and the thief might still be inside the house when
he comes back.
5) HANDOVER
Handover is a special function that the system offers more security to the owner.
a) Handover ON
--- With the handover function enabled, if the Lobby zone
(zone 7) is triggered first, the instant zones (except the 24 hour instant
zone) will follow the zone 7 to give entry delay with the same delay
period. The instant zones will resume to instant mode after the entry
delay expired. With this feature, the owner can set the motion sensors for
MISC.
interior protection with instant zones and the main door protection with
FUNCTIONS
zone 7. The system will always give instant alarm if the person (might be
an intruder) does not enter the house through the lobby zone but break
ON OFF
in from window.
HANDOVER
b) Handover OFF
protection zones keep in their function but not follow the delay time of
zone 7.
NOTE:
The delay zones in the two partitions do not have handover
function.
6) RING-BACK
Ring-back signals are the loud acknowledgement signal coming out from the siren to inform the
owner of the arming and disarming status of the system.
a) Ring-back ON
--- The system energizes the Timing Output Relay twice to
make the siren to generate two short beeps when the system is armed;
ON OFF
and energizes the Output Relay once to generate one short beep when
RINGBACK
the system is disarmed.
b) Ring-back OFF
system is armed or disarmed, no beep is generated as arm-disarm
acknowledgement from siren.
4
HA-263
THE PROGRAMMING JUMPERS
---The system is in normal operation. All the instant
--- The Timing Output Relay does not activate when the