Download Print this page

AEI HA-263K Owner's Manual page 9

8-zone alarm control panel

Advertisement

START THE PROGRAMMING
After the system is set in programming mode, you can program the system with your desired
values of the available options. You can make the programming for all the options continuously or
just select the option(s) that you require. It is not necessary to make the programming in order
sequence; you can jump to any Programming Location that is available in the system.
RECORD A MASTER CODE
MASTER CODE
!
Master Code is the authorization code for setting system into programming mode
!
The master code can be 4 to 6 digits
!
When a new master code is keyed in and confirmed, the old code will be erased
RECORD A USER CODE
LOCATIONS
11
= User Code 1 --- For arm-disarm control of partition 1
12
= User Code 2 --- For arm-disarm control of partition 2
13
= User Code 3 --- For arm-disarm control of the whole system
(partition 1 & 2)
USER CODE
!
The user codes can be 4 to 6 digits
!
When a new code is keyed-in into the location and confirmed, the old code will be replaced.
!
To invalid a code, just key-in the location number followed immediately with [#] key without
program data.
20
(Location 01)
LOCATIONS
USER CODES
VALIDATION
01
4 TO 6 DIGITS
(Locations 11-13)
LOCATIONS
USER CODES
VALIDATION
11
4 TO 6 DIGITS
The back-up battery is not supplied. It is required to purchase separately.
!
The back-up battery should be 12V, 6.5-7.0Ah sealed lead-acid type
!
Replace battery every 3-5 years
!
The back-up time is 16 hours at 250mA
BATTERY CONNECTION
The (+) RED wire connects to the positive terminal of the battery and the ( ) BLACK wire connects
to the negative terminal of the battery. The battery should be a 12V sealed lead acid rechargeable
#
type with a capacity of 6.5-7.0Ah. The battery is protected by a 3A resettable fuse, and it is
charged by a current limiting regulated voltage source in the system.
PERIODIC BATTERY TEST
The system tests the back-up battery automatically once every 24 hours. The test takes around 5
seconds to 2 minutes depending on the condition of the battery. Visual and audible warnings will
be given continuously if the battery is abnormal after testing.
MANUALLY INITIATED BATTERY TEST
Battery test can be initiated manually by momentary turning the key-switch to make contact once
#
at anytime during the system is in Standby mode.
The system can be set to Standby mode for 1 minute by the following ways:
a)
Hold any one of the Partition Arm-Disarm key-switches in making contact for more than 5
seconds during both partitions are in disarmed mode. Ignore the 2 arming beeps and hold the
key switch until the Standby Mode happens.
b)
Switch off both AC and battery power, then power-up again.
REMARKS:
i)
The manually initiated battery test through the key-switch is considered as a beginning of a
new periodic battery test. The system will count the time of 24 hours for the next test from it.
ii)
Battery test will not take place on alarm occur or AC power failure.
iii)
Battery test will stop instantly if alarm occurs or AC power fails during the test.
iv)
The system generates 2 beeps for normal battery, or 5 beeps and than 1 beep/30 seconds
continuously for abnormal battery after battery test.
4
HA-263
HA-263
THE BACK-UP BATTERY
-
9