OPERATING FIREPLACE
Continued
Manual Ignitor
Pilot
Electrode
Burner
Figure 52 - Pilot (Natural Gas)
Manual Ignitor
Pilot
Electrode
Burner
Figure 53 - Pilot (Propane/LP Gas)
B. Using Hand-Held Wireless Remote
Control
1. Set manual ignition bypass switch on con-
trol panel to OFF position (automatic igni-
tion position).
2. Wait five (5) minutes to clear out any gas.
Smell for gas around heater and near floor.
If you smell gas, STOP! Follow "B" in the
safety information on warnings plate. If you
don't smell gas, go to the next step.
3. Point remote control toward the lower front
of fireplace and push both buttons at the
same time. Hold for 6 seconds. The gas
valve will open and electronic ignition will
begin sparking to light the pilot. Note: You
will be able to hear a clicking sound during
this process. LED on wall switch will light.
Note: You may be running this heater for
the first time after connecting to gas supply
or at the start of your heating season. If so,
the ON button may need to be pressed again.
This will allow air to bleed from gas system.
If several attempts to light pilot fail, contact
a qualified service person or gas supplier for
repairs. Until repairs are made, light and op-
erate manually (see Manual Lighting In-
structions for Electrical Power Outage).
4. When pilot flame is lit, the thermocouple
is heated by the flame. When thermocouple
becomes hot (5 to 15 seconds), main burner
will automatically light on high flame.
5. To lower flame, point remote control to-
ward lower front of fireplace and push HI/
LO button once.
Note: This fireplace does not have a pilot-
only mode.
108117-01K
Shutting Off Heater - Wall Switch
Push ON/OFF button on wall switch once.
Automatic
Ignitor
Shutting Off Heater - Wireless Remote
Electrode
Control
Point remote control toward lower front of fire-
place and push both buttons at the same time.
Automatic
Ignitor
Electrode
ate this heater with the fireplace
screen in place. Make sure fire-
place screen is in place before
running heater.
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Open
damper or window to vent smell.
This will only last a few hours.
Because this fireplace has an electronic ignition
system, in the event there is a loss of power, it
will be necessary to manually light the pilot with
the piezo ignitor. After the pilot is lit, the main
burner will light automatically.
1. Follow steps 1 through 3 under Normal
2. Set manual ignition bypass switch on con-
3. The pilot is attached to the rear of the front
Gas Valve
Magnetic
Manual
Override
Handle
www.desatech.com
TO TURN OFF GAS
TO APPLIANCE

MANUAL LIGHTING

INSTRUCTIONS FOR
ELECTRICAL POWER OUTAGE
WARNING: You must oper-
Lighting Instructions, pages 26.
trol panel to ON position (manual ignition
position). See Figure 54.
burner. You will be able to see the pilot and
spark electrode without removing the
screen or logs.
Piezo Ignitor
HI/LO
Button
Wall Switch
Figure 54 - Control Locations
Manual Ignition
Bypass Switch
(Down is ON)
MANUAL
IGNITION
LED
LED
ON/OFF
Button