Manual Lighting - Desa VYGF33PRA Owner's Operation And Installation Manual

Unvented (vent-free) gas fireplace
Hide thumbs Also See for VYGF33PRA:
Table of Contents

Advertisement

OPERATING FIREPLACE
Continued
WARNING: Make sure the selector switch is in the
OFF position when you are away from home for long
periods of time. Fireplace will come on automatically
with selector switch in the ON position.
Pilot Burner
Ignitor
Electrode
Figure 39 - Pilot (Propane/LP)
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set selector switch
in the OFF position to keep from draining the battery.
Shutting Off Burner Only (pilot stays lit)
You may shut off the burner and keep the pilot lit by doing one
of the following:
• Turn control knob clockwise
• Use remote control manual OFF button.
• Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE
1.
Follow steps 1 through 6 under Lighting Instructions, page 18.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 through 11 under Lighting Instructions, page 18.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, pages 35 and 36). Follow instructions
included with the remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on pages 18 and 19.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105270-01H
Ignitor
Pilot Burner
Electrode
Figure 40 - Pilot (Natural)
to the OFF position.
to the PILOT position.
OPERATING FIREPLACE
Lighting Instructions (Cont.)
To Turn Gas Off To Appliance
Manual Lighting Procedure
Optional Hand-Held Remote Operation
1. After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide the selector switch
to the REMOTE position (see Figure 41). Note: The burner
may light if hand-held remote was on when selector switch
was last turned off. You can now turn the burner on and off
with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch in the RE-
MOTE or ON position when the pilot is not lit. This will
drain the battery.
Flame Adjustment Knob
Control Knob in
On Position
Figure 41 - Setting the Selector Switch, Control Knob, and
Flame Adjustment Knob for Remote Operation
ON/OFF SERIES (MODEL GHRCB)
Hold the control button on the hand-held remote until burner
turns on. Hold the control button again until burner turns off
(see Figure 42).
TO LOCK
press both buttons on hand-held remote control until
light stops flashing. Hand-held remote control is now locked. If
the fire is on it will be turned off automatically. In the locked
state, the light will not light up when any button is pressed.
press both buttons together on hand-held remote
TO UNLOCK
control until the light stops flashing. The hand-held remote is
now unlocked.
Figure 42 - On/Off Hand-Held Remote Control Unit (GHRCB)
ON
OFF
REMOTE
Selector Switch in Remote Position
(Optional Hand-Held Remote Control)
Control Button
Turns Burners
On and Off
19
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fpvf33nr millivoltVygf33nraFpvf33pr millivolt

Table of Contents