OPERATING HEATER
Continued
5. Slightly depress and turn control knob
counterclockwise
position. Keep control knob pressed in for
five (5) seconds (see Figure 25).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
6. With control knob pressed in, press and
release ignitor button. This will light pi-
lot. The pilot is attached to the burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not light, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, column 2.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7.
8. Slightly depress and turn control knob
counterclockwise
The burner should light. Set control knob
to any heat level between HI and LO.
Ignitor Button
Figure 25 - Control Knob and Ignitor
Button Location
Ignitor Electrode
Thermocouple
(Note: Appearance of pilot
assembly may vary by model.)
Figure 26 - Pilot
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
to the PILOT
to the HI position.
Control Knob
Pilot
Burner
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
vARIABLE CONTROL
OPERATION
The variable control valve can be set to any
heat setting and flame height desired, by simply
turning the control knob until that setting is
attained. Even the lowest setting provides re-
alistic, dancing yellow flames. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
WARNING: Do not operate
heater between pilot and HI
positions.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN GAS OFF
TO APPLIANCE
Shutting Off Heater
1. Press in and turn control knob clockwise
to the HI position.
2. Turn the control knob clockwise
the PILOT position.
3. Press in control knob and turn clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn the control knob clockwise
the HI position.
2. Press in and turn control knob clockwise
to the pilot position.

MANUAL LIGHTING

PROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 17.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions.