INSTALLATION
Continued
We recommend that you install a sediment trap in
supply line as shown in Figure 25. Locate sedi-
ment trap where it is within reach for cleaning.
Install in piping system between fuel supply and
fireplace. Locate sediment trap where trapped mat-
ter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from
going into fireplace gas controls. If sediment trap
is not installed or is installed wrong, fireplace may
not run properly.
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
Pipe
Cap Tee
Nipple
Sediment Trap
Figure 25 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 41.
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not pro-
vided)
1. If fireplace screen and floor are still installed,
see Removing Fireplace Screen and Floor
Assembly, page 9.
2. Route gas line (provided by installer) from
equipment shutoff valve to fireplace. Route
flexible gas supply line through one of the
access holes.
18
Natural
From Gas Meter
(5" W.C. to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator (11"
W.C. to 14 "
Joint
W.C. Pressure
www.desatech.com
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 26).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
3. Attach the flexible gas line to gas supply (see
Figure 26). Check tightness of flexible gas
line attached to gas regulator of fireplace (see
Figure 26).
4. Check all gas connections for leaks. See
Checking Gas Connections.
5. Replace fireplace floor assembly. Feed flexible
gas line into fireplace base area while replac-
ing fireplace floor assembly. Make sure the en-
tire flexible gas line is in fireplace base area.
Note: Be careful of wires and components on
underside of fireplace floor. Reattach fireplace
floor assembly with screws removed in step 3
of Removing Fireplace Screen and Floor As-
sembly, page 9.
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer
From Gas Meter (Natural)
From External Regulator
(Propane/LP)
Figure 26 - Attaching Gas Lines Together
CHECKING GAS CONNECTIONS
WARNING: Test all gas pip-
ing and connections, internal
and external to unit, for leaks
after installing or servicing. Cor-
rect all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
Flexible Gas Line
from Fireplace
Gas Regulator
108117-01K