OPERATING
FIREPLACE
Contmued
103_o8
TO TURN OFF GAS TO APPLIANCE
Shutting
Off Fireplace
1. Turn control knob clockwise
F_
to the OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting
Off Burner
Only (pilot
stays
lit)
1. Turn control knob clockwise
/_
to the PILOT position.
THERMOSTAT CONTROL OPERATION
II
The thermostatic
control used on this fireplace
differs from standard
thermo-
stats. Standard
thermostats
simply turn on and off the burner. The thermostat
used on this fireplace senses the room temperature.
The thermostat
adjusts the
amount of gas flow to the burner.
This increases
or decreases
the burner flame
height. At times the room may exceed the set temperature.
If so, the burner
will shut off. The burner will cycle back on when room temperature
drops
below the set temperature.
The control knob can be set to any heat level between HI and LO.
Note: The thermostat
sensing bulb measures
the temperature
of air near the
fireplace
cabinet. This may not always agree with room temperature
(depend-
ing on housing construction,
installation
location, room size, open air tempera-
tures, etc.). Frequent
use of your fireplace
will let you determine
your own
comfort levels.
MANUAL LIGHTING
PROCEDURE
1. Follow steps I through 5 under Lighting
Instructions,
pages 19 and 20.
2. With control knob pressed in, strike match. Hold match to pilot until pilot
lights.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
[]