f Level meter display
Displays the level represented by 19 bars. (2 dB increments)
f Standard level bar
At the −18 dB position or the −20 dB position
The setting in [MENU] → [AUDIO SETTINGS] → [AUDIO LEVEL] → [HEADROOM] will be the standard.
6 Warning/error displays
: Warning (details are displayed on the time code display in the following cases)
f [SYSTEM ERROR !]
f [TURN POWER OFF !]
f [REC WARING !]
f [CARD ERROR !] (when recording has stopped)
f [TEMPORARY PAUSE]
: Alert
7 Time code display
f [TCG 12:59:59:20]: Displays the time code generator value.
f [UBG AB CD EF 98]: Displays the user bits generator value.
f [Dur.00:59:59:23]: Displays the duration.
8 CAM INDEX/REEL number recording method display
f F: Recorded as file name.
f M: Recorded in metadata as [TYPE3] of [USER CLIP NAME].
9 CAM INDEX/REEL number
Displays the CAM INDEX, REEL number, and clip number.
10 Lock display/network status display
Displayed when button operations are disabled due to the <LOCK> switch.
The <REC> button is enabled even while lock is active.
When using the wired LAN
f (No display): No compatible device.
(White): Operating but not connected.
f
(Yellow): Operating. A device is connected.
f
(Red): An error has occurred.
f
When using wireless LAN
(Gray): No compatible device.
f
(White): Operating but not connected.
f
(Yellow): Operating. A device is connected.
f
(Red): An error has occurred.
f
When using 4G/LTE (the status of the bar to display changes by the signal status)
(Gray): No compatible device.
f
(White): Operating but not connected.
f
(Yellow): Operating. A device is connected.
f
(Red): An error has occurred.
f
Power supply display
Displays the connection status and remaining capacity of the battery and external power supply.
The remaining capacity information is displayed in "%" if there is any. It is displayed as voltage "V" if % display is not possible.
Displays [EMP] in red character when the end is reached, and [LOW] in yellow character when the near end is reached.
Select [DC POWER SUPPLY] or [BATTERY] to match the power supply to connect in [MENU] → [SYSTEM SETTINGS] → [POWER MANAGEMENT]
→ [DC IN SOURCE] when connecting an external power supply to the <DC IN> terminal.
1
1 <DC IN> power supply display
This is the display when an AC adaptor ([DC POWER SUPPLY]) is connected to the <DC IN> terminal.
2 <DC IN> power supply display
This is the display when a battery is connected to the <DC IN> terminal.
3 Battery display
This is the display when a battery is connected to the battery holder.
4 Battery and <DC IN> power supply display
This is the display when a battery is connected to the battery holder and an AC adaptor ([DC POWER SUPPLY]) is connected to the <DC IN>
terminal.
5 Battery and <DC IN> power supply display
This is the display when a battery is connected to the battery holder and a battery is connected to the <DC IN> terminal.