AZ-10P motion detector

Reports human motion
- 6 -
AZ-10P motion detector
Internal switches:
1
HIGHER ANALYSIS the detector has increased resistance to false alarms and a
slower reaction
STANDARD ANALYSIS the detector has standard resistance to false alarms and a
standard reaction speed
2
INSTANT REACTION the detector does not provide an entrance delay*
DELAY REACTION the detector provides an entrance delay*
*) applies only if a "default" reaction is set for the detector – see the Settings
Frequent movement detection restriction
When in normal operation the detector saves energy by switching the sensor off for 1 minute
each time it detects motion. This ensures that it does not transmit too frequently if there is
frequent movement in the premises.
Battery-low signalling
When the detector batteries are low, Azor sends an informative message. Besides that a
test LED indicator also lights up. If the detector LED is flashing when movement is detected
(outside test mode), the batteries are low.
AZ-10R keyfob
The keyfob can be used for setting and unsetting. It
also enables sending a panic alarm – by pressing both
buttons at the same time. The panic alarm function is
optional – see the Settings. The keyfob battery should
last approx. 2 years. The registration code is sent when
both buttons are pressed for 3 seconds.
The keyfob cannot be used close to the communicator!
AZ-10B doorbell button
Azor has two positions for doorbell button enrollment
(see the Settings). Each position can have a different
melody. The doorbell button battery should last approx. 1
year.
The button should be protected from rain (it is supplied with
a plastic roof).
The button cannot be used close to the communicator.