AZ-10S fire detector
Screw the detector holder to the ceiling
Use the computer to enroll the detector to the system (see the Settings)
Connect the battery and twist the detector onto the holder
Wait until the detector LED indicator goes off (calibration is in progress)
Test the detector – see the Communication check. Activate the detector by pressing and
holding its testing button.
Tips and specifications
The detector cannot be twisted onto the holder if no battery is connected.
Install the detector onto the ceiling in a place with good heat circulation (i.e. avoid corners,
hollows, tops of inclined ceilings, etc.).
If the space (or ceiling) is divided by partitions which prevent free air movement, each
section should have its own detector.
The detector should not be installed close to ventilators, heaters, ventilation openings or in
dusty premises.
It is not recommended to install the detector close to cookers, hot plates or anywhere where
steam is produced.
A suitable place to install a fire detector is a ceiling above the staircase in the house.
Never test the detector with fire; use a special spray designed for smoke detector testing to
simulate fire.
When an alarm is indicated, the siren can be switched off by pressing and holding the test
button.
The detector siren can be disconnected completely – by disconnecting its cable connector
(near the minus pole of the battery).
If people smoke in the room during normal operation, you can program Azor to react only
when set – see the Settings. In such a case disconnect the siren in the detector as well. Do
not forget to ventilate the premises before setting the alarm.
All connecting plugs in the detector must remain disconnected.
Battery-low signalling
When the detector battery is low, Azor sends an informative message. Besides that, the
smoke detector flashes and beeps approx. every 45 s.
The detector reports fire hazards. It is
activated by the presence of smoke or an
abnormal increase in temperature. Besides
sending the information to the system, it also
triggers its own siren during an alarm.
- 20 -

AZ-10D chip reader

Serves for setting and unsetting. It is usually installed at the entrance door.