INSTALLATION
Preparations
- The installation room must be free from the risk of frost.
- The intake temperature of the appliance must be within the
permissible application limits (See 16.3, "Data table", pg.
33).
- The fl oor of the installation room must be level and have suf-
fi cient load bearing capacity. Take note of the weight of the
appliance with a full DHW tank (See 16.3, "Data table", pg.
33). A fl oor with insuffi cient foundation pressure capacity
is in danger of collapse. If the appliance is not evenly bal-
anced, there may be a risk of appliance damage.
- The size of the installation room must correspond to the ap-
plication limits of the appliance (See 10.5, "Minimum clear-
ances", pg. 21 and See 16.3, "Data table", pg. 33).
- Observe the safety clearances and protection zones.
- Always leave suffi cient distance to provide access for installa-
tion, maintenance and cleaning. Observe the required mini-
mum clearances (See 10.5, "Minimum clearances", pg. 21).
- Ensure that the operation of other equipment in the installa-
tion room is not impaired.
- To reduce the pipe runs, install the unit close to the kitchen
or bathroom.
- To prevent disturbance from operating noise, never install
the appliance close to bedrooms.
The following installation locations are not permissible, due to
risk of appliance damage:
- Locations where the air is contaminated with oil or salt
- Saline environments
- Areas in proximity to high frequency machines
- Places where the air contains ammonia (e.g. sewage works)
- Places where the air contains chlorine (e.g. swimming pools)
- Generally places where the air is strongly contaminated, e.g.
due to dust, or contains aggressive substances
Note
The performance data indicated for this appliance has
been determined in line with the relevant standard at an
air temperature of 59 °F (15°C). Below this temperature,
the effi ciency of the appliance decreases.
Note
It is possible to improve the effi ciency of the appliance by
utilizing the waste heat and humidity from other appli-
ances to heat the DHW tank, e.g. boilers, tumble dryers
or freezers.
Sound emissions
The air intake and air discharge sides of the appliance emit more
noise than other sides of the housing.
 Never direct the air intake or air discharge towards
noise-sensitive rooms of the house, e.g. bedrooms.
Note
For details on noise emission, see chapter "See 16.3,
"Data table", pg. 33".
20
| Accelera® 220-300 E

10.4 Siting the appliance

 Carefully undo the cardboard packaging at the clips.
1
1 Cardboard packaging clips
The appliance is secured to the pallet with metal brackets and
screws. The metal brackets are hooked on to the feet underneath
the fl oor plate of the appliance.
1
1.
1 Metal bracket fi xing bolt
 Remove the fi xing bolts of the metal brackets from the pallet.
 Push the metal brackets a little towards the tank center, to
unhook them from the appliance feet.
 Pull the metal brackets out from underneath the appliance.
Material losses
!
Take note of the appliance's weight and top-heaviness.
 Slightly tip the appliance and carefully roll the appliance off
the pallet.
 Bring the appliance in its fi nal location.
2.