Example 4. Foyer Mode
A building owner wants the control panel to arm the
reception area when the tenants have set all of wards
B,C,D,E,F. The first person into the building in the
morning is always the security guard who will only turn off
the reception area as he is not permitted to access the
offices.
Enter Engineer's
Passcode
1234
Then key in:
To:
1
ENT
4
ENT
Assign circuit types.
Assign circuit attributes.
Allocate zones to wards.
1
5
ENT
ENT
Program system timers.
1
6
ENT
ENT
Program setting modes.
4
2
ENT
ENT
Program network equipment
to wards.
4
3
ENT
ENT
Program other equipment
to wards.
Log Off Engineer Mode.
Enter Master User's
Passcode
5678
Then key in:
To:
ENT
ENT
ENT
Enter User Menu 3.
2
ENT
Program Part set Groups.
Log Off User Programming Mode.

Operation:

Assuming the system is fully set, at 7.00am the security
guard enters the reception area and enters his
passcode at the remote keypad in the reception area,
to unset ward A (Foyer). When the next user arrives they
enter their passcode into the keypad which unsets their
own office. This may continue until all offices are unset
by their respective users.
At 6.00pm the security guard leaves the premises. He
locks the main entrance but does not set the system
because one of the staff is working late in the one of the
offices. At 7.00pm the user now wishes to leave the
premises. They unlock the main entrance door and
enter their passcode at the remote keypad.
After leaving and securing the main entrance door the
system sets their ward and, because they are the last
user to set, also sets ward A (Foyer).
Notes:
Assign detectors:
In reception to Ward A,
In each office to respective Ward.
Each ward must have its own exit and
entry delay time. In the example, ward
A and B have entry and exit times of
60s.
Each ward must have its own setting
mode.
Make sure that xnode are assigned
to wards C and E.
Assign keypad in reception to
ward A.
Make sure that tampers are assigned
to the correct nodes.
In the example the panel and bellbox
tamper are assigned to ward A.
Assign Wards B, C, D, E and F to
"Ward A Foyer Mode".
Notes:
Assign ward A to Part set Group 1.
P
P
Ward B
Office Area
Ward B
Ward B
C
P
Ward A
Ward A
C
Reception Area
Ward A
C
Ward A
CP
RK
C
Ward F
Office Area
Ward F
Ward F
P
Key:
Passive Infra-Red Detector
P
Remote Keypad
RK
Users:
No
Type
001
Master
002
Standard Ward
003
Standard Ward
004
Standard Ward
005
Standard Ward
006
Standard Ward
007
Standard Ward
Figure 3. Foyer Mode Example
Note: Do not assign ward A itself to foyer mode, only the
rest of the wards. This means that only the outputs
allocated to ward A will trigger.
TS2500 Hints and Tips
Ward C
Office Area
Ward C
Ward C
C
XN
Ward D
Ward D
C
Office Area
Ward D
C
Ward E
Ward E
Office Area
XN
Ward E
Xnode
XN
CP
Control Panel
Magnetic Contact
C
Wards
A B C D E F
A (Security Guard)
B
C
D
E
F
P
P
5