Advertisement

Quick Links

Document n°1183-1 ~ 27/09/2004
BELFORT GP
FR EN ES ES
PL
Gas stove - EN 613
Model : 154 05 16
Propane gas (type G31)
Technical manual
Category I 3P
to be saved
by the user
for future reference
STAUB FONDERIE
Description of the appliance
Head Office Address
2, rue Saint Gilles
Installation instructions
68230 TURCKHEIM
RC Colmar
Operating instructions
SIREN 439 330 325
Address - Administration and
Spare parts
manufacturing
BP 73
Warranty certificate
59660 MERVILLE (FRANCE)
Telephone : 00 333 28 43 43 43
Fax : 00 333 28 43 43 99
Subject to modifications.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BELFORT GP 154 05 16 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FRANCO BELGE BELFORT GP 154 05 16

  • Page 1 Document n°1183-1 ~ 27/09/2004 BELFORT GP FR EN ES ES Gas stove - EN 613 Model : 154 05 16 Propane gas (type G31) Technical manual Category I 3P to be saved by the user for future reference STAUB FONDERIE Description of the appliance Head Office Address 2, rue Saint Gilles...
  • Page 2: Table Of Contents

    FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the quality of its appliances and is committed to meet its customers’ needs. FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices, uses state-of-the-art technologies to design and manufacture its whole range of products.
  • Page 3: Description Of The Unit

    Belfort GP - ref. 154 05 16 Description of the unit This appliance is a gas stove. WARNING This appliance must be installed in compliance with the rules in force by a competent engineer. The appliance must not be operated if the window is cracked or broken. The safety pilot on the burner must not be adjusted and must not be put out of operation.
  • Page 4: Operating Principle

    Belfort GP - ref. 154 05 16 Description of the unit the Heating Appliance (Fireguards) regulations 1991. Operating principle No part of the window or frame should be permanently removed. It does not give full protection for young The appliance is designed for operating only with the children or the infirm, extra protection should be door closed.
  • Page 5: Installation Instructions

    Belfort GP - ref. 154 05 16 Installation instructions 2. Installation instructions D E P T H The appliance should only be installed by a professional engineer, in the strict application of S H E L . normal practices and all safety precautions. The installation must be carried out according to the Standards and the Building Regulations.
  • Page 6: Mounting The Flue Collar

    Belfort GP - ref. 154 05 16 Installation instructions Smoke exit on the top (fig. 2) Chimney connector Remove the top plate, first remove the 2 screws on the sides of the appliance. The connection to flue must be carried out according to local building regulations.
  • Page 7: Pressure Testing

    Belfort GP - ref. 154 05 16 Installation instructions Pressure Testing Door Lock B u r n e r p r e s s u r e S u p p l y p r e s s u r e The gas pressure to the stove must be measured at the burner test nipple.
  • Page 8: Ceramic Fuelbed Layouts

    Belfort GP - ref. 154 05 16 Installation instructions Ceramic Fuelbed Layouts Place the remaining 5 coals as shown in (B). Replacement coals and ceramic are available from your dealer, but should be installed by acompetent person (e.g. Corgi registered). Please ensure that when fitting the matrix and coals, that you DO NOT OBSTRUCT THE PILOT FRANCO BELGE accept no responsibility for any injury sustained...
  • Page 9: Commissinoing The Stove

    Belfort GP - ref. 154 05 16 Installation instructions • Log Layout Place the “Chared” log in the centre of the fire, on top the Embers and the rear log as shown in the figure. Parts : 1 Ceramic mat, 1 Bag of Ceramic Embers and 4 Logs.
  • Page 10: Instructions For User

    Belfort GP - ref. 154 05 16 Instructions for user 3. Instructions for user Appliance 154 05 16 is set for natural gas (G31) and • Running the appliance at low setting sealed in accordance with category I 3P . Ignite permanent pilot and run appliance at “High”...
  • Page 11: Maintenance

    Belfort GP - ref. 154 05 16 Instructions for user transit. This is a very delicate Electro-magnetic device. Safety devices On propane, the cylinder could be empty. The pilot is not burning or performing correctly? Burner safety : If there are faults in the gas supply or in lighting, the safety device (thermocouple) will shut Ensure the pilot flame is the correct size for the type of down the gas tap automatically.
  • Page 12: Spare Parts

    Liste des pièces de rechange So certain parts of your stove must be replaced, use only parts manufactured by Franco Belge. When ordering spare parts, specify the stove type and serial number, including the colour index (on the guarantee or identification plate), the name of the part and the part number.
  • Page 13 Belfort GP - ref. 154 05 16 Spare parts N° Codes Description ....Type ..A . . B . . C . . D . . E ..Qty 307440 EF Fuel retainer .
  • Page 14 Belfort GP - ref. 154 05 16 Spare parts Figure 6 - Spare parts view Technical manual “1183”...
  • Page 16 § Guarantee certificate § § Legal guarantee replacement of parts covered by the guarantee is found The specifications, dimensions and information shown to be too costly vis-a-vis the price of the appliance, the on our documents are provided for information purposes decision to replace or repair the appliance will be taken only and under no circumstances are binding upon the by the vendor.

Table of Contents