(2) Application software setting
1) Set the PC communication conditions as follows.
Communication speed (bit/second): 115200
Data bit:
Parity:
Stop bit:
Flow control:
2) Select "Start" → "All programs" → "Accessory" → "Communication" → "HyperTerminal" from the
menu of PC and start HyperTerminal.
n
The startup procedure may vary depending on the PC environment.
After startup, a child window of "Connection setting" may be displayed. If it is not displayed, select
"File" → "New connection" from the pull-down menu, and then type the name and select the icon.
(3) Connection check
1) After the communication setting is completed, press the [Enter] key several times.
A mark " → " is displayed in the left edge of the HyperTerminal window.
n
If this mark " → " is not displayed, there may be some failure in the setting or cable connection.
4. Network startup
(1) Type ipAttach (0, "smsc").
(2) Type ifconfig ("smsc0 inet<IP Address>netmask<Subnet Mask>.
Type the IP address of this unit or controller in <IP Address> and type the subnet mask of this unit or
controller in <Subnet Mask>.
If the IP address and subnet mask of this unit are unknown, change the NETWORK switch to PEER
TO PEER, and then type 192.168.0.1 and 255.255.255.0.
If the IP address and subnet mask of controller are unknown, change the NETWORK switch to PEER
TO PEER, and then type 192.168.0.100 and 255.255.255.0.
-> ipAttach(0, "smsc")
value = 0 = 0x0
-> ifconfig("smsc0 inet 192.168.0.1 netmask 255.255.255.0")
value = 0 = 0x0