Transportation Methods; User Responsibility; Fabricator 211I Portable System Package (Part No. W1004201) - Thermal Arc 211i Fabricator Operating Manual

Hide thumbs Also See for 211i Fabricator:
Table of Contents

Advertisement

FABRICATOR 211i

2.05 Transportation Methods

!
ELECTRIC SHOCK can kill. DO NOT TOUCH
live electrical parts. Disconnect input power
conductors from de-energized supply line
before moving the welding power source.
!
FALLING EQUIPMENT can cause serious per-
sonal injury and equipment damage.
Lift Power Source with handles built into the top of the
front and rear molded panels.
Use handcart or similar device of adequate capacity.
If using a fork lift vehicle, place and secure Power Source
on a proper skid before transporting.

2.06 User Responsibility

This equipment will perform as per the information con-
tained herein when installed, operated, maintained and
repaired in accordance with the instructions provided.
This equipment must be checked periodically. Defective
equipment (including welding leads) should not be used.
Parts that are broken, missing, plainly worn, distorted or
contaminated, should be replaced immediately. Should
such repairs or replacements become necessary, it is
recommended that such repairs be carried out by ap-
propriately qualified persons approved by Thermal Arc.
Advice in this regard can be obtained by contacting an
Accredited Thermal Arc Distributor.
This equipment or any of its parts should not be altered
from standard specification without prior written approval
of Thermal Arc. The user of this equipment shall have the
sole responsibility for any malfunction which results from
improper use or unauthorized modification from standard
specification, faulty maintenance, damage or improper re-
pair by anyone other than appropriately qualified persons
approved by Thermal Arc.
INTRODUCTION
WARNING
WARNING
2-2
2.07 Fabricator 211i Portable System
Package (Part No. W1004201)
• Fabricator 211i Power Source
• 12 ft. (3.6 m) Tweco WeldSkill 220 Amp MIG Gun
• Victor Argon Regulator / Flowmeter
• Drive Rolls:
.023"/.030" (0.6/0.8mm) "V" groove,
.023"/.035" (0.6/0.9mm)"V" groove (fitted with .035"
groove lined up) ,
.030"/.035" (0.8/0.9mm) "V" knurled for Flux Cored
Wire,
• Contact Tips (1 each)
.023"(0.6mm),.030"(0.8mm),
.035"(0.9mm) (fitted)
• Electrode Holder with 13 ft. (4m) lead
• Work Clamp with 10ft. (3.1m) lead
• Shielding Gas hose assembly
• 15A/20A Adapter Plug from 208/230V AC 50 Amps
to 115V Amps Circuits
• Thermal Arc Cap
• Electrodes
• Operating Manual
• DVD
Figure 2-1: Fabricator 211i System Packaged W1004201
INTRODUCTION
Manual 0-5157

Advertisement

Table of Contents
loading