Fronius IG Plus 3.0-1 Operating Instructions Manual page 162

For grid-connected photo-voltaic systems
Table of Contents

Advertisement

Fronius IG
Frequency trip limit accuracy
Plus 10.0-1
Frequency clearing times
(continued)
Total harmonic distortion
Power factor
*
General data
Maximum efficiency
CEC efficiency
Consumption in standby (night)
Consumption during operation
Cooling
Protection type
Unit dimensions (w x h x d)
Inverter weight
Wiring compartment weight
Shipping dimensions 42.72 x 20.28 x 14.02 in. + 17.72 x 20.28 x 14.02 in.
(w x h x d)
Shipping weight
Admissible ambient temperature
(with 95% rel. humidity)
Admissible storage temperature
(with 95% rel. humidity)
Protection devices
Ground fault protection internal GFDI (Ground Fault Detector/Interruptor)
Islanding protection
DC reverse polarity protection
Over temperature
assured by electrical design of the inverter.
at 208 V
at 240 V
at 277 V
controlled forced ventilation
1085 x 515 x 356 mm + 450 x 515 x 356 mm
output power derating / active cooling
152
0.05 Hz
0.016 - 300 s
< 3 %
96.2 %
95.0 %
95.5 %
96.0 %
< 1 W
22 W
NEMA 3R
48.07 x 17.09 x 9.61 in.
1221 x 434 x 244 mm
82 lbs.
37 kg
26 lbs.
12 kg
114 lbs.
52 kg
-4 °F - +122 °F
-20 °C - +50 °C
-4 °F - +140 °F
-20 °C - +60 °C
internal
internal diode
1