Technical Data Of The Boilers Kp X2S, Kp X2 - Es - Tetan KP 12S Service And Operation Manual

Automatic boiler
Table of Contents

Advertisement

3

TECHNICAL DATA OF THE BOILERS KP X2S, KP X2 - ES

Table 1
Thermal and technical parameters of products
Parameter
Rated output
Output range
Fuel consumption
Efficiency (rated output)
Efficiency (minimum output)
Temperature of combustion products
Class of the boiler
Hours of burning - min/max – fuel bin 400L
Hours of burning - min/max – fuel bin 700L
*in heating value 17,5MJ/Kg and efficiency 90%
Table 2
Solid harmful substances in combustion
Parameter
Average mass flow rate solid elements
pollutions at rated power
Exhaust mass flow rate on the outlet-nominal output
Exhaust mass flow rate on the outlet-reduced output
Table 3
Technical parameters of products
Parameter
Weight
Water content
Fume duct diameter
Connections: heating and return water
Heating surface
Dimensions (w + d) without ashtray
Dimensions (h)
Working overpressure of water
Hydraul. loss ΔT 10 K
Hydraul. loss ΔT 20 K
Required chimney draft
Recom. operating temp. of heating water
Lowest temperature of incoming water
Table 4
Electrical parameters of products
Parameter
Connecting voltage
Electric input (4 motors, fan)
El. Protection of the control unit
El. Protection of the boiler´s wiring
Table 5
Fuel and its parameters
Wood pellets diameter
Caloric value
Water content
Ash content
Bulk weight
Fuel delivery system
As a guaranteed fuels for all KP boilers are wood pellets, with parameters specified in table 5.
Automatic boiler for wood pellets
Unit
kW
kW
kg x hrs.
%
%
°C
hrs
hrs
Unit
-1
g*hrs
kg/s
kg/s
Unit
kg
litres
Mm
Js
2
m
mm
mm
bar
mbar
mbar
mbar
°C
°C
Unit
W
---
---
bags Big Bag by 800 - 1100 kg, cistern filled
7
KP 12S
KP 22S
KP 12 - ES
KP 22 - ES
19
29
5,5 - 19
8 - 29
-1
~1,3 - 4,4
~1,9 - 6,6
91,2
90,9
90,1
90,1
94 - 151
94 - 148
3
213 – 61
142 - 40
373 – 107
249 - 70
KP 12S
KP 22S
KP 12 - ES
KP 22 - ES
0,36
0,65
0,012
0,018
0,005
0,007
KP 12S
KP 22S
KP 12 - ES
KP 22 - ES
310
370
55
70
130
150
G 1 1/2"
1,8
2,1
477x 980
614x980
1435
1435
in to 2,5
4,77
10,97
1,26
2,77
0,1 – 0,2
60 – 80
55
KP 12S
KP 22S
KP 12 - ES
KP 22 - ES
230 VAC ± 10%, 50 Hz ± 2 Hz
180
210
IP 54
IP 20
6,0 - 8,5 mm
approximately 16-18 MJ / kg
Up to 10 %
Up to 1 % ( 0,8 – 1,0% )
0,6 – 0,64 kg / dm
PE/PP bags 15 – 25 kg,
KP 62S
KP 62 - ES
62
18 - 62
~4,1 – 14,28
90,6
90,1
94 - 140
64 - 19
111 – 33
KP 62S
KP 62 - ES
2,2
0,034
0,016
KP 62S
KP 62 - ES
590
160
160
3,2
845x1360
1720
33,7
8,3
0,3 – 0,4
KP 62S
KP 62 - ES
340
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp 62sKp 12-esKp 22sKp 22-esKp 62-es

Table of Contents