Automatic boiler for wood pellets
6.2
INSTALLATION OF THE BURNER
The burner of the boiler is configured into one unit – the body of the burner + screw feeder + gear unit + motor
+ 2 spirals for electric ignition including needful cable.
Burner has to be placed in a flange on the back side of the boiler and fasten it by nuts M 10 with washers so, that
the non-flammable roupe is fitting evenly and very closely around circumference of the flange.
Connect the cable of the feeder F2 , of the fan. Place the fan in flange.
On the flange determined to a pellet supply connect by flexible hose and attach with fastener.
Insert a boiler thermostat sensor in to a tube placed on flange for pellet supply.
With burner KP62 attach a security thermostat by two straps on a pipe of the fuel input in to a burner.
Picture No. 24 Burner installation
29