Tetan KP 12S Service And Operation Manual page 77

Automatic boiler
Table of Contents

Advertisement

Menu
Menu - name
No.:
MAIN MENU
3.3.2
Ignition
Use electrical ignition
Ignition feeding time
Fan delay after start
Primary fan level in ignition
Control temperature
Reignition enable
Exhaust fan enable
Exhaust fan level in ignition
Maximum ignition time
Burn on time after ignition
Feeding time in burn on
Ignition is running in burn on state
Stabilization time after burn on
Aplication time during burn on
Start program after ignition
3.3.3
Standby mode
Standby time
Time fire life
Boiler standby temperature
Feeder 2 run out in standby
Maximal burnout time fan
Stop the fan in burnout at
Feeding worktime in standby
Feeding breaktime in standby
Number of cycles
Primary fan if feeding in standby
Exhaust fan if feeding in standby
3.3.4
Programs
Program number
Feeder 1 on
Feeder 1 off
Primary fan
Exhaust fan
Menu – description-meaning
Menu for ignition parameters setting
Button for activation of electrical ignition (If set OFF boiler is working in Stand By mode)
Ignition feeding time (feeder F1) – fuel for ignition
Time electrical ignition (preheating) without fan
Primary fan level in ignition
Minimum temperature difference exhaust and boiler water in the end ignition
Permit repetition ignition in case wrong ignition - button
Exhaust fan enable - button
Exhaust fan level in ignition - button
Maximum ignition time (activation electrical heating elements)
Time for stabilization of fire
Feeding time (feeder F1) for stabilization of fire
Time spiral activation - during stabilisation of fire
Time for prolong of stabilization of fire
Aplication time during burn on – additional fuel for burn on
Start program after ignition
Menu Standby mode parameters setting
Time period, in which automatic boiler is not actively burning
Time fire life
Temperature - desired output
Feeder 2 run out in standby
Maximal burnout time fan
Stop the fan in burnout at
Feeding workintime in standby
Feeding breaktime in standby
Number of cycles
Primary fan if feeding in standby
Exhaust fan if feeding in standby
Menu programs parameters setting
Button – No. Program for setting parameters
Program No.1
30% of nominal boiler power
Time for feeding of fuel (feerder 1)
Breaktime of feeder 1
Primary fan settings
Exhaust fan settings
Settings - values
KP 12S,
KP 22S,
unit
KP 12 - ES
KP 22 - ES
-
ON
ON
Sec
90
90
Sec
60
60
%
30
30
°C
10
10
-
OFF
OFF
-
OFF
OFF
%
-
-
Min
15
15
Min
2
2
Sec
5
5
Min
1
1
Min
2
2
Min
0
0
-
3
3
Min
45
45
Min
0
0
in accordance with
in accordance with
°C
the settings
the settings
Sec
60
60
Min
1
1
%
25
25
Sec
5
7
Sec
60
60
-
2
2
%
30
30
%
0
0
Sec
5
5
Sec
90
60
%
30
30
%
0
0
Alloved
KP 62S,
KP 62 - ES
service
ON
producer
40
producer
60
producer
32
producer
10
service
OFF
service
OFF
service
-
producer
15
producer
2
producer
5
producer
1
producer
3
producer
0
producer
3
producer
15
producer
0
in accordance with
user
the settings
producer
60
producer
1
producer
25
producer
5
producer
38
producer
3
producer
30
producer
0
producer
4
producer
30
producer
30
producer
0