Terminal Hzs 555-S With Usb; Description; Cleaning The Touch Screen; Caution - Tetan KP 12S Service And Operation Manual

Automatic boiler
Table of Contents

Advertisement

4.2.2 Terminal HZS 555-S with USB

Picture No. 6
Terminal with USB

4.2.2.1 Description

The HZS 555-S is an intelligent terminal for programming and visualization of automated processes. Process
diagnosis as well as operating and monitoring automated procedures is simplified using this terminal.
A touch screen serves as the input medium for process data and parameters. The output is shown on a 5.7"
SVGA TFT color display.

Cleaning the Touch Screen

Before cleaning the touch screen, the terminal must first be turned off to avoid unintentionally
The terminal's touch screen can only be cleaned with a soft, damp cloth. To dampen the cloth, a screen-cleaning
solution such as an antistatic foam, water with detergent or alcohol should be used. First spray the cleaning fluid
on the cloth and not directly on the terminal. The cleaning solution should not be allowed to reach the terminal
electronics, for example, through the ventilation slots.
No erosive cleaning solutions, chemicals, abrasive cleansers or hard objects that can scratch or damage the
touch screen may be used.
If the terminal is soiled with toxic or acidic chemicals, quickly and carefully clean the terminal to prevent
corrosion.
4.2.2.2

Technical data

Supply voltage
Typically +24 V DC
MIN +18V DC
Current
Typically 440 mA (pro + 24 V) ,
consumption of
Maximum 650 mA
voltage supply
Stadby
Typically 0.56 W
Starting current
Maximum 25 A for 20 μs
Automatic boiler for wood pellets

CAUTION!

triggering functions or commands!
MAX +30V DC
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp 62sKp 12-esKp 22sKp 22-esKp 62-es

Table of Contents