INSTALLATION
1) Unplug the power source.
2) Remove the glass door.
ECS Manual Control Switch Installation:
3) Remove the heat shield from the left side of the faceplate by undoing
the 2 screws. See diagram 1.
Diagram 1
4) Unplug the CAT5 cable from the ECS manual switch included with
the unit. See diagram 2.
5) Remove the 2 bolts, washers, phenolic spacers, split lock washers
and nuts securing the manual control switch to separate the manual
control switch keypad. See diagram 2.
Manual Control
Switch Keypad
Control Switch
Diagram 2
6) Place the ECS manual control switch key pad on the outside of the
opening in the faceplate and the control switch to the inside of the
faceplate.
Align the holes and secure in place using the 2 bolts, washers,
phenolic spacers, split lock washers and nuts. See diagram 3 for
sequence. Diagram 4 shows ECS manual control switch mounted
on faceplate.
16
918-644b

PREMIUM FLUSH FRONT INSTALLATION

PREMIUM FLUSH FRONT INSTALLATION
Left Side
Heat Shield
Bolts
CAT5 Cable
Receptacle
Washer
Phenolic Spacer
Split Lock Washer
Nut
Diagram 4
7) Run the thermodisc wires thru the hole in the heat shield.
Then place the grommet over the sleeve and tuck into the hole in the
heat shield as shown in diagram 5.
Diagram 5
1
IG35
Diagram 3
ECS Manual Switch
Grommet
Regency IG35 Gas Inbuilt Fireplace