LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certified by the Australian
Gas Association for installation and
operation as described in these Installation
and Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
I31-3 Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorised installer, serv-
ice agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-001b
Model:
I31-NG3
I31-LPG3
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
06/01/07

Advertisement

Table of Contents
loading

Summary of Contents for Regency I31-LPG3

  • Page 1 Owners & Installation I31-3 Gas Inbuilt Model: I31-NG3 I31-LPG3 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2: Unit Dimensions

    GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Regency Industries. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model I31-3 of this series has been approved by Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    - Bay Louvres ............11 Hampton Cast Faceplate Installation ......12 Warranty ............... 27 Hampton Cast Grill Installation ........13 Barossa Curved Front ..........14 Optional Remote Control ..........15 Optional Wall Thermostat ........... 15 Wiring Diagram ............15 Regency I31-3 Gas Fireplace Inbuilt...
  • Page 4: Safety Label

    DATA BADGE This is a copy of the label that accompanies DATA BADGE NOTE: Regency units are con- stantly being improved. Check the label on the each Regency I31-3 Gas Inbuilt fireplace. We unit and if there is a difference, the label on the have printed a copy of the contents here for unit is the correct one.
  • Page 5: Installation

    This appliance may only be 8) Install the log set. See page 8. installed in a flued, non-combustible fire- The Regency Gas Fireplace must be installed in place. The appliance and flue should be 9) Assemble and install the faceplate and trim.
  • Page 6: Minimum Fireplace Dimension

    Hearth Depth 405 mm framing is made of metal studs Hearth Width J 1015 mm covered with a non-combustible board. Min. Alcove Width K 1220 mm Max. Alcove Depth L 915 mm Regency I31-3 Gas Fireplace Inbuilt...
  • Page 7: Draft Diverter Connection

    3.6 m. is recommended. house. The Regency Inbuilt Fireplace incorporates its own internal draft diverter, so no additional 2) Light the unit and set controls to maximum. external draftdiverter is required.
  • Page 8: Optional Brick Panel

    PASS OR DISCONNECT THIS SWITCH. nation around the firebox base. Vermiculite and Vermiculite and embers. Vermiculite and embers. embers. 3) Place Rear Log A)02-43 on the two pins on the rear log support. Diagram 3 Regency I31-3 Gas Fireplace Inbuilt...
  • Page 9 Logs A)02-43, C)02-56, and B)02-45 in position C)02-56 B)02-45 6) Place the Left Top Log D)02-46 on the pin B)02-45 on Log C)02-56 and on top of the cutout G)02-44 on Log A)02-43. Bracket Notch Regency I31-3 Gas Fireplace Inbuilt...
  • Page 10: Faceplate & Trim

    10) Attach the faceplate panels* to the inbuilt fireplace body using the 4 remaining black screws. See diagram 5. 11) Push the Regency logo plate into the two Diagram 2 holes in the bottom left corner of the face- Rear View: Trim Assembly plate.
  • Page 11: Flush Louvres

    Note: The top and if the louvre needs to be adjusted; bend the bottom trim piec- bracket out as shown in the diagram. es are different, check diagrams above and below. 3) Install top and bottom louvres. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 12: Hampton Cast Faceplate Installation

    Attach the clip to the rear of the faceplate to ensure that the wires do not touch the side of the unit. 10) The power cord should be run behind the faceplate panel. 28" Regency I31-3 Gas Fireplace Inbuilt...
  • Page 13: Hampton Cast Grill Installation

    Secure using 2 screws per hinge. 13) To put on the Regency logo, peel the sticker from the back of the logo and place it centered on the bottom left hand corner of the faceplate.
  • Page 14: Barossa Curved Front

    3. 2) Pull down louver. 3) Fix brackets onto firebox, one on each side using 1 screw per side. Secure with screw. Secure bracket 6) Close louver. with screw. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 15: Optional Remote Control

    Wiring errors can cause Caution: Ensure that the wires do not cle. Do not cut or remove the grounding prong improper and dangerous touch any hot surfaces and are away from this plug. operation. from sharp edges. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 16: Operating Instructions

    3) Push in the gas control knob slightly and turn clockwise to "OFF". Do not force. Blower: Regency gas appliances use high tech blow- 4) Disconnect all electric power and gas to the ers to push heated air farther into the room. It appliance if service is to be performed.
  • Page 17: Copy Of Lighting Instruction Plate

    The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). Regency uses StoveBrite Paint - Metallic Black #6309. 3) Make a periodic check of burner for proper position and condition.
  • Page 18: Maintenance

    ICING AN APPLIANCE MUST BE thermopile. REPLACED PRIOR TO OPERAT- Your Regency stove is supplied with high ING THE APPLIANCE. temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce.
  • Page 19: Glass Gasket

    6) Remove the Grate by removing the screws haven't come loose. on each side of the grate. Remove the 2 screws holding the grate in position. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 20: Trouble Shooting

    MAINTENANCE TROUBLE SHOOTING REGENCY GAS SPACE HEATER SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION 1) Thin black coating [soot]forms on view- a) Incorrect gas pressure Check and correct gas pressure if sooting ing glass. b) Not enough combustion continues open aeration shutter on burner.
  • Page 21: Parts List

    Flush Louvre set - Steel/Black (Top & Bottom) 26) 400-990 Bay Louvre set - Black (Top & Bottom) 400-992 Bay Louvre set - Gold/Black (Top & Bottom) 400-993 Bay Louvre set - Steel/Black (Top & Bottom) Regency I31-3 Gas Fireplace Inbuilt...
  • Page 22 93) 902-231 Left Top Log 94) 902-232 Center Log 95) 902-226 Middle Right Log 96) 902-230 Middle Left Log 97) 902-229 Front Right Log 98) 902-228 Front Left Log *Not available as a replacement part. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 23: Faceplate Assembly

    403-913 Faceplate & Trim Compelte - Oversize 320-946 Hearth Trim 6" - Oversize 141) * Faceplate Side Right - Oversize 142) * Faceplate Top - Oversize *Not available as a replacement part. 143) * Faceplate Side Left - Oversize Regency I31-3 Gas Fireplace Inbuilt...
  • Page 24 Bay Door Trim Set - Steel 160) 403-927 Barossa Curved Front 111) * Bay Door Trim Top 112) 904-196 1" Round Ceramic Magnet *Not available as a replacement part. 113) * Bay Door Trim Bottom Regency I31-3 Gas Fireplace Inbuilt...
  • Page 25 Flush Glass Frame 194) * Mounting Flange 207) 402-981 Cast Grill (Set) - Top & Bottom - Black Metallic 402-986 Cast Grill (Set) - Top & Bottom - Black Enamel *Not available as a replacement part. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 26 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Regency I31-3 Gas Fireplace Inbuilt...
  • Page 27: Warranty

    Regency, may nullify your warranty on this product. Electrical components such as blowers, switches, wiring, Regency Industries Ltd., shall in no event be liable for any thermodiscs, remote control, thermopiles, thermocouples special, indirect consequential damages of any nature and gas valves are covered for one year from the date of purchase.
  • Page 28 © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

I31-ng3

Table of Contents