Regency IG34-LPG Owners & Installation Manual

Gas inbuilt

Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certifi ed by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
IG34 GAS INBUILT
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-793a
Models:
REFERENCE
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
IG34-NG
IG34-LPG
IG34-ULPG
04/28/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IG34-LPG and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency IG34-LPG

  • Page 1 Installation and service must be performed by an authorised installer, service agency or the gas supplier. 918-793a Models: IG34-NG IG34-LPG IG34-ULPG FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electri- cal switch: do not use any phone in your building.
  • Page 2: Unit Dimensions

    GAS INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The model IG34 of this series has been approved by Australian Gas Association for both safety and effi...
  • Page 3: Table Of Contents

    Remote Control ...23 Summary of Controls ...23 Fan Operation...23 Copy Of Lighting Instruction Plate ...24 Normal Operating Sounds Of Gas Appliances ...24 Resetting the unit...24 Regency IG34 Gas Inbuilt Fireplace TABLE OF CONTENTS MAINTENANCE Door Glass ...25 Replacement ...25 Glass Gasket ...25 Fan Maintenance ...26...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies each Regency IG34 Gas Inbuilt fi replace. We have printed a copy of the contents here for your review. DATA BADGE NOTE: Regency units are constantly being improved. Regency Gas Fireplace...
  • Page 5: Installation

    IMPORTANT MESSAGE The Regency Gas Inbuilt must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Note: Failure to follow these instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage.
  • Page 6: Minimum Fireplace Dimensions

    INSTALLATION MINIMUM FIREPLACE DIMENSIONS The minimum fi replace dimensions for the Regency gas space heater are shown in the following diagrams: CLEARANCES TO COMBUSTIBLES Minimum Clearances to Combustibles From Unit Sides 10" / 255mm Ceiling 47.5" / 1205mm Mantel 13" / 330mm Max.
  • Page 7: Flue Liner Installation

    "I", seal connection with high temperature silicone. Secure with gear clamp. Install to AS5601 (Australia) / NZS 5262 (New Zealand) Regency IG34 Gas Inbuilt Fireplace Be careful not to damage thermal insula- tion when sliding on vent connector plate. This could cause blockage.
  • Page 8: Installation In Masonry Or Zero Clearance Chimney

    See the appliance manufacturer's instructions for de- tails. Make sure the Flex Liners do not sag behind the appliance. Finally, move the appliance into its appropri- ate place. Mount the Adaptor to the Baseplate using sheet metal screws. Regency IG34 Gas Inbuilt Fireplace...
  • Page 9: Aeration Settings

    Regency IG34 Gas Inbuilt Fireplace System Data IG34 IG34-NG: For 0 to 610 meters altitude IG34-LPG: For 0 to 610 meters altitude IG34-ULPG: For 0 to 610 meters altitude Burner Inlet Orifi ce Sizes: ULPG Burner Max. Input 31.7 mj...
  • Page 10: Conversion Kit #486-968 For Ng To Lpg Model

    15) Remove the control box cover by undoing the 3 screws. Manoeuvre through antenna. Antenna Control Box Cover 16) Remove the jumper using a plier. Jumper Location Jumper 17) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2. Regency IG34 Gas Inbuilt Fireplace...
  • Page 11 NOTE: The outlet pressure must be set to minimum 1.6 kPa. Cable Electric Modulator Regency IG34 Gas Inbuilt Fireplace INSTALLATION After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifi ce of the pressure.
  • Page 12: Conversion Kit #486-967 For Ng To Ulpg

    15) Remove the control box cover by undoing the 3 screws. tenna. Maneuver through an Antenna Control Box Cover 16) Remove the jumper using a plier. Jumper Location Jumper 17) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2. Regency IG34 Gas Inbuilt Fireplace...
  • Page 13 NOTE: The outlet pressure must be set to minimum 1.6 kPa. Cable Electric Modulator Regency IG34 Gas Inbuilt Fireplace INSTALLATION After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifi ce of the pressure.
  • Page 14: Optional Stainless Steel Inner Panel Install

    2 screws (ones that were removed initially). Reinstall the logs, glass door, inner door frame with screen and fi nally the faceplate. See manual for detailed instructions. Final installation of optional stainless panels. Larger fold in the metal. Regency IG34 Gas Inbuilt Fireplace...
  • Page 15: Log Set Installation

    2) Sprinkle the vermiculite around the fi rebox base. Take some of the embers (approx. 1/3 of the bag) and sprinkle over the vermiculite. Regency IG34 Gas Inbuilt Fireplace LOG SET INSTALLATION Vermiculite and embers 3) Place Rear Log A)02-43 on the two pins on the rear log support.
  • Page 16 8) Position notch in Front Right Log F)02-48 on Log E)02-47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner. A)02-43 Cutout E)02-47 A)02-43 B)02-45 Notch Cutout Notch F)02-48 B)02-45 Regency IG34 Gas Inbuilt Fireplace Bracket...
  • Page 17 9) Place Front Left Log G)02-44 onto the 2 front pins as shown. G)02-44 Regency IG34 Gas Inbuilt Fireplace Front edge of 10) Place the embers and Rockwool on the exposed front rear burner burner tray.
  • Page 18: Glass Door Installation

    Repeat for 2nd spring. See diagram 3. To remove the fl ush door, reverse the above steps. To remove the fl ush door, reverse the above steps. Diagram 1 Diagram 2 Diagram 3 Regency IG34 Gas Inbuilt Fireplace...
  • Page 19: Faceplate & Optional Plinth Trim Assembly

    1) Hook the screen over the top of the door frame - lower until screen is fl ush with the door frame. Regency IG34 Gas Inbuilt Fireplace SCREEN INSTALLATION 2) Flip door frame and screen over - locate the bracket tab at the bottom of the door frame - fold the tab over 90º...
  • Page 20: Faceplate And Door Frame Installation

    6) Install the door frame by hooking the top fl ange over the top of the glass door. Glass Door 7) Lower the door frame gently into place. 8) To uninstall - reverse procedure. Metal Lip Completed Faceplate & Door Frame Installation Door Frame with Safety Screen Regency IG34 Gas Inbuilt Fireplace...
  • Page 21: Thermodisc Installation

    2 screws as shown below. Thermodisc Bracket Back of Faceplate Regency IG34 Gas Inbuilt Fireplace THERMODISC INSTALLATION 5) Secure wiring along the vertical right side of the faceplate (facing the back of the faceplate) with supplied grey adhesive clips. 6) Slide unit into fi nal position.
  • Page 22: Final Check

    WIRING This unit is polarity sensitive and will not operate if polarity is incorrect. STANDARD WIRING CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency IG34 Gas Inbuilt Fireplace...
  • Page 23: Operating Instructions

    DO NOT BURN THE APPLIANCE WITH- OUT THE GLASS FRONT IN PLACE. REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter and a wall mounting plate.
  • Page 24: Regency Ig34 Gas Inbuilt Fireplace

    Blower: Regency gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON.
  • Page 25: Maintenance Instructions

    DOOR GLASS REPLACEMENT Your Regency stove is supplied with high tem- perature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass...
  • Page 26: Fan Maintenance

    9) Carefully slide the fan to the front, rotate it 45 degrees and slide it out simultaneously with the ECS box. Resistor Fan Ground Connectors Connectors Cable 10) Disconnect all the connectors from the fan and resistor. 11) Remove the fan ground cable. 12) Reverse the above steps to install the new fan. Regency IG34 Gas Inbuilt Fireplace...
  • Page 27: Valve Assembly Replacement

    7) Remove the fi rebox base plate by removing the 10 screws which hold it in place. 8) Remove all the wire connectors from the valve and spark ignitor. 9) Remove the valve tray assembly. 10) To replace the valve tray assembly, simply reverse the above steps. Regency IG34 Gas Inbuilt Fireplace...
  • Page 28: Parts List

    The Control Box Cable wires for the IG35 come separately: 910-530, 910-504, 910-528 910-936 910-082 910-089 910-088 910-080 FG37 FG38 FG39 PG33 PG36D N/A* 910-912 910-906 910-083 910-514 910-916 PG36 HG35 PG121/PG131 IG35 N/A* Regency IG34 Gas Inbuilt Fireplace IG34...
  • Page 29: Main Assembly

    910-080 SIGMA Valve 845 336-001 Valve Tray Gasket** 402-526 Grate Assembly** 336-535 Burner Assembly - NG/LPG 402-935 Log Set** Regency IG34 Gas Inbuilt Fireplace MAIN ASSEMBLY Part # 10) 910-936 910-947 11) 904-240 904-645 12) 336-013 13) 936-155 14) 940-307/P...
  • Page 30: Faceplate Assembly

    PARTS LIST Part # Description 336-914 Faceplate & Trim Complete - Regular 366-942 Plinth Kit 336-532 Flush Screen Door** *Not available as a replacement part. FACEPLATE ASSEMBLY Regency IG34 Gas Inbuilt Fireplace...
  • Page 31: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of FPI.
  • Page 32 FIREPLACE PRODUCTS AUSTRALIA PTY. LTD. 21-23 SOUTH LINK, DANDENONG SOUTH VICTORIA, 3175 AUSTRALIA © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Ig34-ngIg34-ulpgIg34

Table of Contents