LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certified by the Australian
Gas Association for installation and opera-
tion as described in these Installation and
Operating Instructions.
Your unit should be serviced annually by
an authorised service person.
IG35 Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-448e
Models:
IG35-NG
IG35-LPG
IG35-ULPG
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
04/09/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IG35-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency IG35-NG

  • Page 1 Owners & Installation IG35 Gas Inbuilt Models: IG35-NG IG35-LPG IG35-ULPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2: Unit Dimensions

    GAS INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model IG35 of this series has been approved by Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    Premium Flush Front Installation .........16 Main Assembly ............29 Remote Control ............21 Burner Assembly & Log Set.........29 Final Check..............21 Faceplate Assembly ............30 Standard Wiring ............21 Premium Flush Front Assembly........30 Wiring with Premium Flush Front Option .....22 WARRANTY Warranty ..............31 Regency IG35 Gas Inbuilt Fireplace...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies DATA BADGE NOTE: Regency units are con- each Regency IG35 Gas Inbuilt fireplace. We stantly being improved. Check the label on the have printed a copy of the contents here for unit and if there is a difference, the label on the your review.
  • Page 5: Installation

    Installation is to be carried out ONLY by an authorised person. The Regency Gas Fireplace must be installed The Regency Gas Insert is installed as listed in accordance with these instructions. Carefully below. 1) The appliance shall be installed in accord- read all the instructions in this manual first.
  • Page 6: Minimum Fireplace Dimensions

    Mantel Clearances DIMENSIONS CLEARANCES TO COMBUSTIBLES The minimum fireplace dimensions for the Regency gas space heater are shown in the The minimum fireplace clearances for the following diagrams: Regency gas space heater are shown in the following diagrams: From Unit:...
  • Page 7: Flueing

    3.45 kPa (14" w.c.). minimum flue height of 1.5 m. is recommended. Maximum Outlet Pressure The Regency Inbuilt Fireplace incorporates The manifold pressure is controlled by a 7) Gas Outlet Pressure Electric Modulator its own internal draft diverter, so no additional...
  • Page 8: Aeration Settings

    TEST FOR FLUE System Data BRICK PANEL IG35 SPILLAGE IG35-NG: For 0 to 610 meters altitude 1) Unwrap the brick panels from the protective A " spillage" test must be made before the IG35-LPG: For 0 to 610 meters altitude wrapping.
  • Page 9: Conversion Kit For Ng To Lpg

    Jumper Location 5) Remove the grate. Jumper 6) Remove the burner and adjust the aeration setting to 15 mm fully open. Heat Shield 15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2. Regency IG35 Gas Inbuilt Fireplace...
  • Page 10 Electric gas leaks. Modulator 19) Check operation of flame control. 20) Check for proper flame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. Regency IG35 Gas Inbuilt Fireplace...
  • Page 11: Conversion Kit For Ng To Ulpg

    Jumper Location 5) Remove the grate. 6) Remove the burner and adjust the aeration Jumper setting to 15 mm fully open. Heat Shield 15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2. Regency IG35 Gas Inbuilt Fireplace...
  • Page 12 Electric gas leaks. Modulator 19) Check operation of flame control. 20) Check for proper flame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. Regency IG35 Gas Inbuilt Fireplace...
  • Page 13: Log Set Installation

    - do not force into position. 6) Place Front Left Log C)02-44 onto the 2 front pins as shown. 2) Sprinkle the embers on the front, left and right sides of the firebox base. Lava Rock C)02-44 Embers Embers Regency IG35 Gas Inbuilt Fireplace...
  • Page 14 If there is any flame of the burner port. hesitation, check the area for any blockage of the burner port. Example 3 Regency IG35 Gas Inbuilt Fireplace...
  • Page 15: Faceplate, Trim & Louver Installation

    INSTALLATION 10) Push the Regency logo plate into the two FACEPLATE, 4) Connect the fan harness to the fan switch. holes in the bottom left corner of the face- TRIM & LOUVER plate. 5) Connect the valve harness to the valve on/off switch.
  • Page 16: Premium Flush Front Installation

    Align the holes and secure in place using the 2 bolts, washers, phenolic spacers, split lock washers and nuts. See diagram 3 for sequence. Diagram 4 shows ECS manual control switch mounted on faceplate. Diagram 5 Regency IG35 Gas Inbuilt Fireplace 06/23/08 918-644b...
  • Page 17 Run the CAT5 cable from the unit thru the cable ties on the heat shield and tighten cable ties. Ensure not to overtighten. Cut excess cable tie. See diagram 8. CAT5 Cable Diagram 10 Diagram 8 Regency IG35 Gas Inbuilt Fireplace 918-644b 06/23/08...
  • Page 18 Faceplate Installation: Diagram 15 15) Completely mount the faceplate to the unit. .See diagram 13. 18) Undo the wire clip to the right side of the valve. See diagram 16. Diagram 16 Diagram 13 Regency IG35 Gas Inbuilt Fireplace 06/23/08 918-644b...
  • Page 19 See diagram 22. Connect the 2 wires from the thermodisc to the appropriate wire on Diagram 18 the harness; female to male, male to female. Bracket Diagram 22 Bracket Diagram 19 Regency IG35 Gas Inbuilt Fireplace 918-644b 06/23/08...
  • Page 20 3 screws on each side. See diagram 25. The fan should run at least on low speed to prevent the unit from overheating which will cause automatic shutdown via the thermodisc safety switch. Bottom Louver Diagram 25 Regency IG35 Gas Inbuilt Fireplace 06/23/08 918-644b...
  • Page 21: Remote Control

    INSTALLATION REMOTE CONTROL FINAL CHECK Use the Regency Remote Control Kit approved Before leaving this unit with the customer, the for this unit. Use of other systems may void installer must ensure that the appliance is firing your warranty. correctly. This includes:...
  • Page 22: Wiring With Premium Flush Front Option

    (grounding) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Regency IG35 Gas Inbuilt Fireplace...
  • Page 23: Operating Instructions

    2 to restart the unit. SHUTDOWN INSTRUCTIONS 1) Press the ON/OFF switch once. 2) The LED will flash. 3) Turn off all electric power to the appliance if service is to be performed. Regency IG35 Gas Inbuilt Fireplace...
  • Page 24: Copy Of Lighting Instruction Plate

    Blower: and any gas control which has been under water. Regency gas appliances use high tech blowers WHAT TO DO IF YOU SMELL GAS to push heated air farther into the room. It is not...
  • Page 25: Maintenance

    OR GUARD REMOVED FOR SERV- INSTRUCTIONS ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- Your Regency stove is supplied with high tem- Any maintenance required accessing the perature, 5 mm Neoceram ceramic glass that glass door of the unit must be performed ING THE APPLIANCE.
  • Page 26: Fan Maintenance

    9) Remove the fan ground cable. 10) Pull out the fan tray. 11) Remove the 3 screws from the back of the fan tray to remove the fan. 12) Reverse the above steps to install the new fan. Regency IG35 Gas Inbuilt Fireplace...
  • Page 27: Removing

    Glass Door Holder 15) Remove the 2 screws which secure the valve tray. Use a long Philips screwdriver for easy access. 12) Remove the firebox base plate by removing 11 screws which hold it in place. Regency IG35 Gas Inbuilt Fireplace...
  • Page 28: Parts List

          *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 The Control Box Cable wires for the IG35 come separately: 910-530, 910-504, 910-528 Regency IG35 Gas Inbuilt Fireplace...
  • Page 29: Main Assembly

    Burner Assembly - NG/LPG Middle Left Log 63) 910-034 Pilot Assy (NG) - 3 flame convertible top Front Right Log 910-035 Pilot Assy (LPG) - 3 flame convertible top Front Left Log *Not available as a replacement part. Regency IG35 Gas Inbuilt Fireplace...
  • Page 30: Faceplate Assembly

    PREMIUM FLUSH FRONT ASSEMBLY Part # Description 486-916 Premium Flush Front - Black 486-949 Wiring 486-932 Flue Free Kit 910-987 Thermodisc 200) * Screen 201) * Heat Deflector 202) * Heat Shield *Not available as a replacement part. Regency IG35 Gas Inbuilt Fireplace...
  • Page 31: Warranty

    The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing. Repair/replacement parts purchased by the consumer from Regency ® after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only.
  • Page 32 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.