Advertisement

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
IG34 GAS INBUILT
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-793d
Models:
REFERENCE
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
IG34-NG
IG34-LPG
IG34-ULPG
04.08.15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IG34 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency IG34

  • Page 1 Owners & Installation IG34 GAS INBUILT Models: IG34-NG IG34-LPG IG34-ULPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2: Unit Dimensions

    Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model IG34 of this series has been approved by Australian Gas Association for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Electronic Components Parts List .......28 Standard Flush Door ...........18 Main Assembly ............29 Optional Flush Trim ............Faceplate Assembly ............30 Faceplate & Optional plinth trim Assembly ....19 Faceplate and door frame Installation ......20 WARRANTY Thermodisc installation ..........21 Warranty ..............34 Regency IG34 Gas Inbuilt Fireplace...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies each Regency IG34 Gas Check the label on the unit and if there is a difference, the label on the Inbuilt fireplace. We have printed a copy of the contents here for your unit is the correct one.
  • Page 5: Installation

    BEFORE YOU START INSTALLATION CHECKLIST Installation is to be carried out ONLY by an The Regency Gas Inbuilt must be installed in accordance with these instructions. Carefully authorised person. Before installing vent system ensure that the read all the instructions in this manual first.
  • Page 6: Minimum Fireplace Dimensions

    FLUEING DIMENSIONS THE APPLIANCE MUST NOT The minimum fireplace dimensions for the BE CONNECTED TO A Regency gas space heater are shown in the CHIMNEY FLUE SERVING A following diagrams: SEPARATE SOLID FUEL BURNING APPLIANCE AND MUST BE TERMINATED TO THE OUTDOORS.
  • Page 7: Flue Liner Installation

    Secure with gear clamp. with a 1/8" wide flat screwdriver. Install to AS5601 (Australia) / 3) Attach manometer to "IN" and/or "OUT" NZS 5262 (New Zealand) pressure tap(s) using a 5/16" (8mm) ID hose. Regency IG34 Gas Inbuilt Fireplace...
  • Page 8: Installation In Masonry Or Zero Clearance Chimney

    7) Attach the Flex Liner ends at the top of the chimney to the Co-Linear to Co-Axial Adaptor. Use four sheet metal screws to connect each Flex Liner run to the Adaptor. 8) Twist lock the Vertical Termination Cap to the Adap- tor. Regency IG34 Gas Inbuilt Fireplace...
  • Page 9: Aeration Settings

    INSTALLATION System Data IG34 IG34-NG: For 0 to 610 meters altitude IG34-LPG: For 0 to 610 meters altitude IG34-ULPG: For 0 to 610 meters altitude Burner Inlet Orifice Sizes: ULPG Burner Max. Input 31.7 mj 30.6 mj ULPG 26.4 mj Min.
  • Page 10: Conversion From Ng To Lpg

    ULPG" Jumper over top of the serial number decal. Note: Aeration settings do not need 17) Reverse steps 13, 12, 11, 6, 5, 4, 3 to be adjusted. & 2. Regency IG34 Gas Inbuilt Fireplace 03/11/09 918-823...
  • Page 11 Cable 22) Check operation of fl ame control. Electric Modulator 23) Check for proper fl ame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. Regency IG34 Gas Inbuilt Fireplace 03/11/09 918-823...
  • Page 12: Conversion From Ng To Ulpg

    ULPG" over top of the serial number decal. Jumper Note: Aeration settings do not need to be adjusted. 17) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2. Regency IG34 Gas Inbuilt Fireplace 03/11/09 918-824...
  • Page 13 Cable 22) Check operation of fl ame control. Electric 23) Check for proper fl ame appearance and glow on logs. Modulator Installer Notice: These instructions must be left with the appliance. Regency IG34 Gas Inbuilt Fireplace...
  • Page 14: Optional Stainless Steel Inner Panel Install

    2 screws (ones that were removed initially). Reinstall the logs, glass door, inner door frame with screen and fi nally the faceplate. See manual for detailed instructions. Final installation of optional stainless panels. Regency IG34 Gas Inbuilt Fireplace 918-833 04/20/09...
  • Page 15: Log Set Installation

    The logs are fragile, handle with care - do not force into position. 2) Sprinkle the vermiculite around the fi rebox base. Take some of the embers (approx. 1/3 of the bag) and B)02-45 sprinkle over the vermiculite. 908-783a 03/30/09 Page 1 of 3 Regency IG34 Gas Inbuilt Fireplace...
  • Page 16 E)02-47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner. Notch D)02-46 F)02-48 A)02-43 C)02-56 Bracket B)02-45 Cutout 908-783a 03/30/09 Page 2 of 3 Regency IG34 Gas Inbuilt Fireplace...
  • Page 17 G) 02-48 A) 02-43 D) 02-46 G)02-44 F) 02-47 E) 02-45 B) 02-56 C) 02-44 The "02" refer numbers (i.e. 02-43) are molded into the rear of each log. Regency IG34 Gas Inbuilt Fireplace 908-783a Page 3 of 3 03/30/09...
  • Page 18: Glass Door Installation

    Repeat for 2nd spring. See diagram 3. To remove the flush door, reverse the above steps. Diagram 3 To remove the flush door, reverse the above steps. Regency IG34 Gas Inbuilt Fireplace...
  • Page 19: Faceplate & Optional Plinth Trim Assembly

    Take the top faceplate and align the holes in it with the holes in the side panels. Secure with provided nuts and bolts. Install faceplate on unit - see next page. IG34 Faceplate Assembly / Plinth 336-914 Faceplate / Trim Kit...
  • Page 20 Thermodisc Note: Ensure that the fl anges on the sides of the fi rebox are on the outside, when installing the faceplate (see below). Bracket Faceplate Flange on fi rebox Back of Faceplate Regency IG34 Gas Inbuilt Fireplace 02/04/13 918-825c...
  • Page 21: Faceplate And Door Frame Installation

    6) Push both bottom frame hinges down on the metal lip until they are fully seated. 7) Install lower screw below glass door - secure with 4 screws. Completed Faceplate & Door Frame Installation with Safety Screen 8) Flip bottom louver up to close. Regency IG34 Gas Inbuilt Fireplace 02/04/13 918-825c...
  • Page 22: Final Check

    CAUTION: Label all wires prior to disconnection not operate if polarity is incorrect. touch any hot surfaces and are away when servicing controls. Wiring errors can cause improper and dangerous operation. from sharp edges. STANDARD WIRING Regency IG34 Gas Inbuilt Fireplace...
  • Page 23: Operating Instructions

    REMOTE CONTROL INSTRUCTIONS Set the fan speed on the control panel at the top Use the Regency Remote Control Kit approved rear of the unit to adjust to the desired speed. 1) Plug the power cord into a power outlet.
  • Page 24: Copy Of Lighting Instruction Plate

    Blower: Regency gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON.
  • Page 25: Maintenance

    DO NOT TOUCH GLASS scratched if abrasives are used to clean UNTIL COOLED them. Your Regency stove is supplied with high tem- NEVER ALLOW CHILDREN TO TOUCH GLASS perature, 5 mm Neoceram ceramic glass that The heater is finished in a heat resistant...
  • Page 26: Fan Maintenance

    9) Carefully slide the fan to the front, rotate it 45 degrees and slide it out simultaneously with the ECS box. Resistor Fan Ground Connectors Connectors Cable 10) Disconnect all the connectors from the fan and resistor. 11) Remove the fan ground cable. 12) Reverse the above steps to install the new fan. Regency IG34 Gas Inbuilt Fireplace...
  • Page 27: Valve Assembly Replacement

    7) Remove the firebox base plate by removing the 10 screws which hold it in place. 8) Remove all the wire connectors from the valve and spark ignitor. 9) Remove the valve tray assembly. 10) To replace the valve tray assembly, simply reverse the above steps. Regency IG34 Gas Inbuilt Fireplace...
  • Page 28: Parts List

       910-527 Manual Control Switch    910-935 Manual Control Switch      *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 Regency IG34 Gas Inbuilt Fireplace...
  • Page 29: Main Assembly

    Neoceram Glass 910-080 SIGMA Valve 845 948-223 Logo Plate 336-001 Valve Tray Gasket** 918-793 Manual 402-526 Grate Assembly** 336-535 Burner Assembly - NG/LPG *Not available as a replacement part. 402-935 Log Set** ** Part not shown. Regency IG34 Gas Inbuilt Fireplace...
  • Page 30: Faceplate Assembly

    PARTS LIST FACEPLATE ASSEMBLY Part # Description 366-942 Plinth Kit 336-914 Faceplate & Trim Complete - Regular 336-532 Flush Screen Door** *Not available as a replacement part. Regency IG34 Gas Inbuilt Fireplace...
  • Page 31 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ Regency IG34 Gas Inbuilt Fireplace...
  • Page 32 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ Regency IG34 Gas Inbuilt Fireplace...
  • Page 33 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ Regency IG34 Gas Inbuilt Fireplace...
  • Page 34: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 35 03 9799 7277 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency IG34 Gas Inbuilt Fireplace...
  • Page 36 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

Table of Contents