Regency Cascades I1150 Owners & Installation Manual

Wood insert

Advertisement

Cascades™
I1150
Wood Insert
Owners & Installation Manual
www.regency-fire.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
0219WN027S
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
920-132
09.03.19

Advertisement

Table of Contents
loading

Summary of Contents for Regency Cascades I1150

  • Page 1 Cascades™ I1150 Wood Insert Owners & Installation Manual www.regency-fire.com Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 0219WN027S FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 920-132 09.03.19...
  • Page 2 Model Regency I1150 – 1.7g /hr. “This manual describes the installation and operation of the Regency I1150 wood heater. This heater meets the 2020 U.S. Environmental Protec- tion Agency’s cord wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates rang- ing from 12,800 BTU/hr to 39,100 BTU/hr.”...
  • Page 3: Table Of Contents

    CAUTION: To avoid burns or wood splinters, when opening/closing the fuel door or adding wood to the fire, You should always wear appropriate protective gloves to protect your hands from the heat being emitted from this fireplace. I1150 Regency Wood Insert...
  • Page 4: Copy Of The Safety Label For I1150

    CERTIFIÉ CONFORME AUX NORMES 2020 DU U.S. ENVIRONMENTAL PROTECTION AGENCY EN MATIÈRE D'ÉMISSION DE PARTICULES DE BOIS EN UTILISANT LE BOIS DE CORDE. HOMOLOGUÉ AVEC LA ASTM E3053. MODÈLE REGENCY I1150 –1.7 G /H. CET APPAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE INSPECTÉ PÉRIODIQUEMENT ET RÉPARÉ POUR FONCTIONNER CORRECTEMENT. CONSULTER LE MANUEL D’INSTALLATION POUR PLUS D’INFORMATION.
  • Page 5: Dimensions

    6" (152mm) Diameter STANDARD FLUE ADAPTOR *1-1/2" (38mm) *Measurement from back of faceplate to fuel door opening Regency Inserts are designed to use either a 5.5" (140mm) or 6" (152mm) flue. I1150 Regency Wood Insert...
  • Page 6: With Offset Flue Adaptor

    6" (152mm) Diameter OFFSET FLUE ADAPTOR *1-1/2" (38mm) *Measurement from back of faceplate to fuel door opening Regency Inserts are designed to use either a 5.5" (140mm) or 6" (152mm) flue. I1150 Regency Wood Insert...
  • Page 7: Installation

    Regency Inserts are designed to use either a 10. Installer must mechanically attach the supplied 5.5" (140mm) or 6" (152mm) flue. label to the inside of the firebox of the fireplace 2.
  • Page 8: Masonry And Factory Built Fireplace Clearances

    Please check to ensure that your floor protection and hearth will meet the standards for clear- ance to combustibles. Your hearth extension must be made from a non-combustible material. Extending 16" for US and 18" for Canada—measured from the fuel loading door. I1150 Regency Wood Insert...
  • Page 9: Installing Your Insert

    10. Re-install the door if removed prior to installation. Flue Adaptor Diagram 2 Secure adaptor using 3 screws - 1 in the Pull Rod In Place front and 1 each on the left and right side. Diagram 5 I1150 Regency Wood Insert...
  • Page 10: Installation Into A Masonry Fireplace

    948-412/P 6" Flue Offset Adaptor (offsets back 4") 846-527 Flue Connector Kit 3. In most cases opening the existing spark screens fully should give enough room for the insert installation. If it does not, remove and store. I1150 Regency Wood Insert...
  • Page 11: Faceplate, Trim & Optional

    Faceplate, Trim & Optional Bottom Faceplate & Fan Support Installation Regular Faceplate Dimensions (shown with bottom faceplate/fan support attached): 38” (965mm) 38” (965mm) Oversize Faceplate Dimensions (shown with bottom faceplate/fan support attached): 44” (1118mm) 44” (1118mm) 03/10/19 920-023 I1150 Regency Wood Insert...
  • Page 12 Diagram 2 Tool holder Diagram 2A Diagram 4 If the insert is going to sit on the hearth proceed to "Faceplate Trim Installation" (step 8) otherwise con- tinue on to "Bottom Faceplate Installation" (step 4). I1150 Regency Wood Insert 920-023 03/10/19...
  • Page 13 (Black Trim included with Regular/Oversize Faceplate brackets and tighten to secure in place. Secure the Regency logo or Bottom Faceplate) plate to the bottom of the faceplate.
  • Page 14 Diagram 6. 22) Re-attach the fan/fan support assembly to the ash lip of the insert. Diagram 9: Rear / Bottom View Note: Fan not exactly as shown Completed Faceplate Assembly Faceplate Side 920-023 03/10/19 I1150 Regency Wood Insert...
  • Page 15: Fan / Blower

    Grounding #8 Groun Lug Lug Detail Ground wire from fan Lockwasher Star washer Star washer Ground wire from power cord Wire98gr.eps updated Jan. 27/00 updated: Aug. 09/05 capitalized the word Nut I1150 Regency Wood Insert BLACK BLACK...
  • Page 16: Brick Installation

    4.250 x 8.000 x 30 DEG BRICK 802-147 3.500 x 4.500 BRICK 802-152 2.000 x 9.000 BRICK 902-111 9.000 x 4.500 STANDARD BRICK RD-14289 4.500 x 7.000 BRICK RD-14288 4.250 x 7.000 BRICK ITEM PART NUMBER QTY. DESCRIPTION I1150 Regency Wood Insert...
  • Page 17: Baffle Installation

    Note: It will be easier to remove the air tubes by removing both the bottom right base brick and right side wall brick. Baffle bracket 3. Install the center baffle. Centre baffle 4. Install the right and left side baffles (right side baffle shown below). Baffle bracket I1150 Regency Wood Insert...
  • Page 18: Glass Replacement

    Glass Replacement Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only.
  • Page 19: Wood Door & Handle Assembly

    (Refer to Diagram 1) Door hinges Wood handle Door Door handle Hinge Cap Cover Diagram 2 tooltip Diagram 3 I1150 Regency Wood Insert 919-967 01.25.19...
  • Page 20: Stainless Steel Smoke Deflector Installation

    WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure deflector is seated so bolts are seated at the bottom of the slot before tightening. Smoke deflector installed with 2 bolts. Note: This is a cutaway view from the back of the unit I1150 Regency Wood Insert...
  • Page 21: Seasoned Wood

    Install the operating handle storage bracket on the top left side (facing back of unit) of the faceplate. Loosen the two 7/16” bolts and slide bracket in and retighten bolts. Diagrams below show bracket already installed. Loosen these two bolts and slide in the bracket. I1150 Regency Wood Insert...
  • Page 22: Operating Instructions

    THIS UNIT IS DESIGNED TO BURN SEASONED to start a fire. Before establishing your first fire, it your Regency Stove causing a draft down your CORDWOOD ONLY. COAL AND BRIQUETTES is important that you fully understand the operation chimney.
  • Page 23: Ash Disposal

    OIL. SOME FUELS COULD GENER- 1. Do not allow ashes to build up to the loading 7. Your Regency stove can be very hot. You may be ATE CARBON MONOXIDE AND ARE doors! Only remove ashes when the fire has seriously burned if you touch the stove while it is VERY DANGEROUS.
  • Page 24: Maintenance

    When ignited, this creosote can result in an extremely hot fire. If the door gasket requires replacement 5/8" diameter material must be used. Regency uses a gasket rope The chimney connector and chimney should be 7/8" (Part #846-570). A proper high temperature inspected at least once every two months during gasket adhesive is required.
  • Page 25: Secondary Air Tube Removal / Installation

    C-Cast Baffles, then remove the remaining 2 tubes. 2. Unscrew 7/64" Allen key screw counterclockwise. Once the screw is com- pletely loose, remove and drop the handle down off the door handle shaft and replace with new handle. I1150 Regency Wood Insert...
  • Page 26: Vertical Stainless Deflector Replacement

    2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical baffle. 3. Repeat steps to install new vertical deflector. NOTE: ENSURE BAFFLE IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX. I1150 Regency Wood Insert...
  • Page 27 When cleaning the chimney system the air tubes, baffles should be removed for ease of cleaning. See manual for details on removal. We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special vacuum cleaner designed to deal with fine particles. I1150 Regency Wood Insert...
  • Page 28: Parts

    Baffle Holder (Each) 106-129 Control Tool 172-016 Control Tool Slide 075-062 Primary Air Cover Plate 075-037 SS Smoke Deflector 172-032/P Heat Shield 911-096 120 Volt Power Cord 948-444 Regency Flame Logo Silver 075-021 Firebox Floor Gasket I1150 Regency Wood Insert...
  • Page 29 I1150 Regency Wood Insert...
  • Page 30: Brick Panels

    4.250 x 8.000 x 30 DEG BRICK 802-147 3.500 x 4.500 BRICK 802-152 2.000 x 9.000 BRICK 902-111 9.000 x 4.500 STANDARD BRICK RD-14289 4.500 x 7.000 BRICK RD-14288 4.250 x 7.000 BRICK ITEM PART NUMBER QTY. DESCRIPTION I1150 Regency Wood Insert...
  • Page 31: Faceplates

    Black Perimeter Trim Black Regular Faceplate N/S 171-572 Black Perimeter Trim Black Oversize Faceplate N/S 948-223 Regency Logo Plate N/S 171-526 Faceplate Mounting Brackets (Each) N/S 171-546 Faceplate Hardware Package *Not available as a replacement part. I1150 Regency Wood Insert...
  • Page 32: Warranty

    At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. Revision Date: July 2019 Regency Wood Products Warranty I1150 Regency Wood Insert...
  • Page 33 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: July 2019 Regency Wood Products Warranty I1150 Regency Wood Insert...
  • Page 34 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 35 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 36 I1150 Regency Wood Insert...
  • Page 37 I1150 Regency Wood Insert...
  • Page 38 I1150 Regency Wood Insert...
  • Page 39 I1150 Regency Wood Insert...
  • Page 40 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Printed in Canada Regency is a trademark of FPI Fireplace Products International Ltd. © Copyright 2019, FPI Fireplace Products International Ltd. All rights reserved.

Table of Contents