Further details regarding the individual steps

Returning the DHW cylinder to use

A Flange lid
B Gasket
1. Reconnect the DHW cylinder to the
pipework.
2. Insert new gasket B underneath
the flange lid A.
Checking all gas equipment for soundness at operating pres-
sure
Danger
Escaping gas leads to a risk of
explosions.
Check gas equipment for
soundness.
Initial start-up, inspection, maintenance
(cont.)
C Earth cable
D Push-on tab
3. Fit the flange lid and tighten the
screws with a maximum torque of
25 Nm.
4. Push earth cable C onto push-on
tab D.
5. Fill the cylinder with potable water.