Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code in
comp.
the dis-
play
b4
X
X
b5
X
X
b7
X
X
b8
X
X
bA
X
bC
X
bd
X
bE
X
bF
X
74
System char-
Cause
acteristics
Controls as if
Internal fault
the outside
temperature
was 0 °C
Control opera-
Internal fault
tion as per the
delivered con-
dition
Burner
Boiler coding
blocked
card fault
Burner
Flue gas
blocked
temperature
sensor break
Mixer "Close"
Communica-
tion fault –
extension kit
for heating
circuit M2
Control mode
Communica-
without remote
tion fault -
control
Vitotrol re-
mote control,
heating cir-
cuit A1
Control mode
Communica-
without remote
tion fault -
control
Vitotrol re-
mote control,
heating cir-
cuit M2
Control mode
Vitotrol re-
mote control
incorrectly
encoded
Control mode
Incorrect
LON com-
munication
module
Remedy
Replace control
unit
Replace control
unit
Plug in boiler cod-
ing card or re-
place, if faulty
Check flue gas
temperature sen-
sor
Check the exten-
sion kit connec-
tions and coding;
start the exten-
sion kit
Check connec-
tions, cable/lead
and coding ad-
dress "A0"
Check connec-
tions, cable/lead
and coding ad-
dress "A0"
Check remote
control DIP switch
setting (see
page 105)
Replace the LON
communication
module