Viessmann Vitodens 333 Service Instructions Manual page 77

Compact gas fired condensing boiler
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Fault codes
(cont.)
Fault
Const.
Weath.-
code in
comp.
the dis-
play
E6
X
X
F0
X
X
F1
X
X
F2
X
X
F3
X
X
F4
X
X
F7
X
X
System char-
Cause
acteristics
Burner fault
Flue gas/
ventilation
system
blocked
Burner
Internal fault
blocked
Burner fault
Flue gas
temperature
limiter has
responded
Burner fault
The tem-
perature lim-
iter has
responded
Burner fault
Flame signal
is already
present at
burner start
Burner fault
No flame sig-
nal.
Burner
Differential
blocked
pressure
sensor faulty
Troubleshooting
Remedy
Check the flue
gas/ventilation
system and differ-
ential pressure
sensor; press "E"
Replace control
unit
Check flue gas
path/route, press
"E"
Check the heating
system fill level,
the circulation
pump, the tem-
perature limiter
and interconnect-
ing cables/leads;
ventilate the sys-
tem; press "E"
Check the ionisa-
tion electrode and
interconnecting
leads; press "E"
Check the ionisa-
tion electrode,
ignition, ignition
module, intercon-
necting cables
and leads, gas
pressure, gas
combination valve
and the ionisation
current; press
"E"
Check differential
pressure sensor
and lead
77