Introduction; Models; Features; Technical Specifications - DSC TL260GS Installation Manual

Ethernet/internet and gsm/gprs dual-path alarm communicator; gsm/gprs wireless alarm communicator
Hide thumbs Also See for TL260GS:
Table of Contents

Advertisement

Available languages

Available languages

The GS2060/GS2065 Communicators are GSM/GPRS wireless alarm communicators that send alarm communication to Sur-Gard
SystemI, II and III monitoring station receivers through the GSM/GPRS digital cellular network.
The TL206GS/TL265GS Communicators are dual-path alarm communicators that send alarm communication to Sur-Gard SystemI, II
and III monitoring station receivers through the Ethernet/Internet or the GSM/GPRS digital cellular network.
The performance of the TL260GS/TL265GS/GS2060/GS2065 Communicator depends greatly on GSM network coverage. It should
not, therefore, be mounted without first performing placement tests to determine the best location for reception (minimum of one green
LED On). Optional antenna kits are available.

Models

The following models are compatible with PC1616/PC1832/PC1864 control panels:
• GS2060 (GSM/GPRS only)
The following models are compatible with PC9155 control panel:
• GS2065 (GSM/GPRS only)

Features

• Fully redundant Ethernet/Internet and GSM/GPRS dual-path alarm communication (TL260GS/TL265GS only)
• Back up or primary GSM/GPRS alarm communication
• Ethernet LAN/WAN 10 BaseT or 10/100 BaseT (TL260GS/TL265GS only)
• Integrated call routing
• Panel remote uploading/downloading support via GSM/GPRS and Ethernet/Internet
• Supervision heartbeats via GSM/GPRS and Ethernet/Internet
• 128-bit AES encryption via GSM/GPRS and Ethernet/Internet (NIST Validation Certificate No. 995)
• Full event reporting
• SIA format
• Signal strength and Trouble display
• Individual Ethernet and/or GPRS Periodic test transmission
• Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz

Technical Specifications

The input voltage to the TL260GS/TL265GS/GS2060/GS2065 Communicator can be drawn from the UL/ULC Listed Control Panel or
provided by an external UL Listed power supply rated for the application (external power-limited source).
NOTE: The power supply must be Class II, Power Limited.
UL/ULC Installation Requirements
NOTE: For equipment used at the protected premises and intended to facilitate IP communications (hubs, routers, NID, DSL/Cable
modems) 24h back-up power is required. Where such cannot be facilitated, a secondary (back-up) communication channel is required.
Notes for using Private, Corporate and High Speed Data Networks:
Network access and domain access policies shall be set to restrict unauthorized network access, and 'spoofing' or 'denial of service'
attacks. Select the internet service providers that have redundant servers/systems, back-up power, routers with firewalls enabled and
methods to identify and protect against 'denial of service' attacks (i.e. via 'spoofing').
Notes for using Public Switched and Wireless Data Networks:
Communication channels shall be facilitated such that the communicator will restrict unauthorized
access, which could otherwise compromise security. Communicators shall be located in secured areas.
• For ULC Residential fire and burglary applications the TL260GS/GS2060/TL265GS/GS2065 can be used as primary communication
channel via either GSM or IP or as a back-up in conjunction with the DACT. Test transmission every 24h shall be enabled on each
channel.
• For ULC Commercial Fire and Burglary applications the TL260GS/GS2060 can be used as a passive communication module with the
Security Levels P1 (each channel GSM or IP independent), P2 (GSM and IP in back-up configuration, panel section [851] section
[005] option [5] OFF) or P3 (GSM and IP in redundant configuration, panel section [851] section [005] option [5] ON). The module
can be also used as an Active communication system with the security Levels A1-A4 (each channel GSM or IP independent or
together in a back-up/redundant configuration). For Active Line Security systems the encryption AES128 bit shall be enabled and the
supervision heartbeat rate shall be selected as 90s (panel section [851], section [004] = 005A). The supervision window at the
SRC's receiver shall be programmed as max. 180s.
• For UL Residential fire and burglary applications the TL260GS/GS2060/TL265GS/GS2065 can be used as primary communication
channel via either GSM or IP (200s supervision enabled is required for burglary applications, using standard/encrypted line security)
or as a back-up in conjunction with the DACT (30 days test transmission required on each channel).
• For UL Commercial Burglary applications the TL260GS/GS2060 module can be used as Dual Signalling Line communication system
(GSM and IP channels used in redundant configuration), Standard Line Security and as Encrypted Line Security. The supervision
heartbeat shall be enabled (panel section [851] section [005] option [1] (IP) and/or option [2] (GSM) shall be ON), option [3] shall be
ON and the supervision heartbeat rate shall be selected as 135s section [004] = 0087. The supervision window at the supervising
station shall be max. 200s ). For Encrypted Line Security systems the encryption AES128 bit shall be enabled.
• For UL Commercial Burglary installations, the TL260GS and GS2060 are listed as a primary (sole) communication means (heartbeat
must be enabled) or for supplementary (back-up) use in conjunction with a POTS line (dialer). When the heartbeat transmission over
the Ethernet or GSM-GPRS network is enabled, using the TL260GS or GS2060 with a compatible control unit listed for standard/
encrypted line security, it can provide line security for the alarm system over the primary line.
• The TL260GS and GS2060 are also suitable to be used with a compatible control unit listed for dual line security transmission when
used in conjunction with a DACT or a PSDN transmitter, where the PSDN provides the line security and is the primary line. In this
mode, alarm signals are required to be sent simultaneously over both communication methods.

INTRODUCTION

• TL260GS (Ethernet/Internet + GSM/GPRS dual-path)
• TL265GS (Ethernet/Internet + GSM/GPRS dual-path)
• PC-Link connection
• SIM card included
• Activating, initializing and remote programming through Connect 24