D. Deodorizing Control
i. Control condition
Control at cooling/soft dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during freeze prevention control.
ii. Operation
The odor status is arranged as below and it is shifted as follows.
* When COMP is ON
* When COMP is OFF
* Start from 4 if the Thermostat is OFF during the start operation.
8.4.1.8.
Airflow Direction
1. There is one type of airflow, vertical airflow (directed by horizontal vane).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
Vertical Airflow
Operation Mode
Heating
Cooling, Soft Dry and Ion
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1
below. When the air conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the
positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to
close position.
(Shift to 4 when COMP is OFF)
(Shift to 1 when COMP is ON)
Auto with Heat Exchanger
Temperature
Manual
Auto
Manual
1 → 2 → 3
4 → 5 → 6 → 7 → 6 ←→ 7
Airflow Direction
A
Upward fix
B
Downward fix
C
Downward fix
D
Downward fix
82
Vane Angle (°)
1
2
3
4
70
70
20
20
20
20 ~ 70
20
5
70
70