8.1.1.14. Auto Restart Control
• If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous
operation mode and airflow direction. (Timer Delay Safety Control is valid.)
1. Control start conditions
• The 24-hour timer must not be set.
• The sleep timer must not be set.
Auto start control is not available when timer or sleep mode is set.
2. Description of control
• In the case of manual operation, the operation mode, temperature setting, fan speed and airflow direction before the power
is turned off are restored.
• In the case of automatic operation, after the power is restored operation starts with the determination of the mode.
• While the air conditioner odour clear timer has been set, the setting is cancelled, and operation is transferred to the mode
before the power is turned off.
• While the air conditioner odour clear operation (with timer / without timer setting) are being performed, both of these
operations are completed, and operation is transferred to the operation mode prior to these operations.
Example: When the power is turned off during an outdoor unit cooling operation.
8.1.1.15. Indication Panel
LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode
judgment, or delay ON timer sampling.
• If timer LED is blinking, there is an abnormality operation occurs.
• If ionizer LED is blinking, there is an abnormality of ionizer occurs.
TIMER
QUIET
Orange
Orange
Timer Setting ON
Quiet Mode ON
Timer Setting OFF
Quiet Mode OFF
49
POWERFUL
ION
Orange
Green
Powerful Mode ON
Ion Mode ON
Powerful Mode
Ion Mode OFF
OFF
ALLERGEN
BUSTER
Blue
Operation ON
Operation OFF