8.4.1.7.
Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Soft Dry, Fan]
Remote Control
Tab (rpm)
PSHi
CS-E15DB4EW
600
CS-E18DB4EW
640
[Heating]
Remote Control
Tab (rpm)
PSHi
CS-E15DB4EW
650
CS-E18DB4EW
690
O
O
SHi
Hi
Me+
600
560
520
640
590
550
O
O
SHI
Hi
Me+
650
600
570
690
640
600
O
O
Me
Me-
480
440
400
510
470
430
O
O
Me
Me-
540
510
480
570
530
490
78
O
Lo
Lo-
SLo
350
310
390
350
O
Lo
Lo-
SLo
460
300
470
320
SSLo
200
200
SSLo
300
300